摘要 以旋流板塔为主设备,采用二级还原碱液吸收法处理某化工厂含氮氧化物废气(4500 m3/h),在液气比3.6 L/m3条件下,治理后排放的氮氧化物平均浓度从初始的791 mg/m3降至96 mg/m3,平均排放速率从3.37 kg/h削减至0.41 kg/h,平均去除效率达到87.8%。 The application of deoxidize alkali absorb process in 4500 m^3/h NOx waste gas was introduced. The scrubber used in this process was a rotating-stream-tray (RST) column. The results indicated that the average concentration of NOx was decreased from 791 mg/m^3 to 96 mg/m^3, and the average discharged rate was decreased from 3.37 kg/h to 0.41 kg/h when the liquid-gas ratio was about 3.6L/m^3. Meanwhile, the average denitrification efficiency of the process could reach up to 87.8%.
出处 《科技通报》 2007年第5期751-754,共4页 Bulletin of Science and Technology
基金 国家自然科学基金(20276067) 国家863计划(2002AA649310)资助项目
关键词 旋流板塔 氮氧化物 空气污染控制 rotating-stream-tray nitrogen oxide air pollution control
  • 相关文献

参考文献4

  • 1Wendt JOL,Linak WP,Groff PW and Srivastava RK,Hybrid SNCR-SCR technologies for NOx control:modeling and experiment[J].AIChE 2001,47:2603-2617.
  • 2Wang CB,Yeh TF and Lin HK,Nitric oxide adsorption and desorption on alumina supported palladium[J].Hazard Mater 2002,92:241-251.
  • 3张秋望 沈少华 谭天恩.NOx湿法治理的研究及应用.环境污染与防治,1987,5(9):32-34.
  • 4国家环境保护总局 《空气和废气监测分析方法》编委会编.空气和废气监测分析方法(第四版)[M].北京:中国环境科学出版社,2003-09..