期刊文献+

核电站用屏蔽泵的抗震力学性能计算分析 被引量:7

Seismic analysis on canned motor pump used in nuclear power generating station
下载PDF
导出
摘要 以核电站用屏蔽泵为研究对象,采用有限元法,对其施加满足实际工况的约束,计算出屏蔽泵的自振频率和振型。同时对屏蔽泵在地震载荷、自重、扭矩等多种载荷组合作用下进行了抗震性能分析,计算结果表明在上述载荷作用下,屏蔽泵的应力状况满足抗震要求,泵轴的变形在允许限值内。 In this paper, canned motor pump used in nuclear power generating station is studied, the finite element model of the pump with contraints conformed to real work conditions is established, the frequencies and modal shapes of the pump are given. And the seismic performance analysis of the pump is carried out under the combined loads including earthquake load, dead weight and torque. The results show that the stress of the canned motor pump conforms to the seismic requirements for equipment of the nuclear power generating station, and the pump shaft deformation is within the allowable limits.
出处 《世界地震工程》 CSCD 北大核心 2007年第3期47-53,共7页 World Earthquake Engineering
基金 国家科技基础条件平台重点工作项目(2004DEA70940)
关键词 有限元法 抗震性能 屏蔽泵 finite element method seismic analysis canned motor pump
  • 相关文献

参考文献5

二级参考文献8

  • 1团体著者,核电厂抗震设计规范,1993年
  • 2团体著者,日本核电厂结构.设备及管道抗震设计(译),1989年
  • 3胡聿贤,地震工程学,1988年
  • 4团体著者,国外核电站抗震规范选编,1982年
  • 5陈世坤.电机设计[M].北京:机械工业出版社,2005.
  • 6核电厂抗震设计规范[S].国家地震局主编,北京:中国计划出版社.
  • 7ANSI/ASME BPV-Ⅲ-1-NC,锅炉及压力容器规范美国国家标准[S].
  • 8孙柏涛,刘殿魁,丰彪.巴基斯坦恰希玛核电站用P300工程核级冷冻机组抗震力学性能计算分析[J].地震工程与工程振动,2000,20(2):61-67. 被引量:5