期刊文献+

两种取材方法快速诊断流感病毒感染的对比研究 被引量:4

Contrast Study of Different Collection Methods to Detection of Influenza Virus Infection
下载PDF
导出
摘要 目的比较咽部分泌物咽拭子取材和负压吸引鼻导管取材的优越性。方法采用咽拭子和负压吸引鼻导管两种方法取咽部分泌物,分别用GICA法、免疫荧光法检测30例急性呼吸道感染患者的咽部分泌物中的流感抗原。结果30例急性呼吸道感染者中GICA法检出流感A阳性3例、B阳性2例;免疫荧光法检出A、B阳性各3例,其中5例与GICA法相同。GICA法中,咽拭子取材检出流感A、B阳性各2例;鼻导管取材检出流感A阳性3例,B阳性2例,两种取材方法阳性检出率相比,差异无统计学意义(P>0.05)。结论咽拭子取材法检测流感抗原可信、可靠且较负压吸引鼻导管法方便快捷。 Objective To compare the superiority of different collection methods for pharynx nasalis secretion by throat swab and nasal catheter. Methods Pharynx nasalis secretion of 30 patients with acute respiratory tract infection was tested via throat swab and nasal catheter by means of gold immunochromatography assay ( GICA ) and immunofluorescence assay ( IFA ). Results No obvious difference in positive rate was found between the two collection methods for pharynx nasalis secretion. Conclusion The collection methods by throat swab is rapid in the detection of influenza virus antigen.
出处 《临床军医杂志》 CAS 2007年第5期750-751,共2页 Clinical Journal of Medical Officers
基金 军队"十一五"科技攻关项目(06G026)
关键词 流感病毒 快速诊断 胶体金免疫层析法 influenza virus rapid test gold immunochromatography assay
  • 相关文献

参考文献5

  • 1何小维,赵喜红,刘晓云,黄强.胶体金快速诊断技术的研究进展[J].中国人兽共患病学报,2007,23(1):86-88. 被引量:25
  • 2张德玺,韩洪彦,王希良.一种快速检测甲型流感病毒的方法[J].中国比较医学杂志,2007,17(1):42-45. 被引量:25
  • 3Hmstech A,Friis S,Grauballe P C,et al.Detection by Elisa of IgA and IgM antibodies in secretion and IgM antibodies in serum inprimary tower respiratory syncytial virus infection[J].Med Virol,1982,17 (2):149-154.
  • 4Ray C G,Minnich L L.Efficiency of immunofluorescence for rapid detection of commom respiratory viruses[J].Clin Microbiol,1987,25(2):355-357.
  • 5陈杭薇 尤兰花.成人呼吸道病毒、肺炎衣原体、支原体感染研究.中华医院感染学杂志,2003,13(4):308-310.