期刊文献+

空调装置蒸发器管排数与迎面风速关系探析及应用

Relationship of tube row number and face velocity in an evaporator for air conditioning unit and its application
下载PDF
导出
摘要 针对传统的空调装置蒸发器设计时管排数取值的不确定性,从分析表冷器冷却效率的影响因素入手,研究了管排数和迎面风速之间的内在关系,得到了管排数的计算公式。通过实例探讨了管排数确定性在蒸发器设计过程中的应用。 For the uncertainty in selection of the tube row number in evaporator design,analyses influencing factors of the cooling efficiency on surface air coolers,studies the internal relationship between the tube row number and the face velocity,and obtains calculating formulas.Discusses its effect with an application example.
出处 《暖通空调》 北大核心 2007年第9期79-81,34,共4页 Heating Ventilating & Air Conditioning
关键词 空调装置 蒸发器 管排数 迎面风速 air conditioning unit,evaporator,tube row number,face velocity
  • 相关文献

参考文献3

  • 1上海冷气机厂.JB/T 7659.5-95 氟利昂制冷装置用翅片式换热器[S].北京:中国标准出版社,1995
  • 2日本冷冻协会.冷冻空调新技术--基础篇[M].北京:中国商业出版社,1980
  • 3McQuiston F C.Heat,mass and momentum transfer data for five plate-fin-tube heat transfer surfaces[G]//ASHRAE Trans,1978,84 (1):226-293