摘要 采用气液混合泵投加臭氧,限制引风机出口臭氧浓度在0.2mg/m3以下,在直接蒸发冷却空调样机上进行了循环水净化动态试验。32天的运行结果表明,臭氧投加量为0.03~0.09g/(m3.h),浓缩倍数由1.5逐步提高到4.5,杀菌、缓蚀、阻垢效果明显。对该方法的工业应用提出了建议。 Adopting a gas-liquid mixing pump for putting ozone into water and limiting the ozone concentration at outlet of draught fan lower than 0.2 mg/m^3,carries out the dynamic simulation experiment on a sample equipment of direct evaporative cooling air conditioner.The operation results of 32 days show that the amount of ozone is from 0.03 g/(m^3·h)to 0.09 g/(m^3·h),and that the concentration weight is improved from 1.5 to 4.5,and that the bactericidal,anticorrosion and anti-scale effects are obvious.Proposes some measures for practical application.
机构地区 西安工程大学
出处 《暖通空调》 北大核心 2007年第9期148-150,共3页 Heating Ventilating & Air Conditioning
基金 陕西省教育厅专项科研计划资助项目(编号:07Jk248)
关键词 臭氧 蒸发冷却空调 循环水 阻垢 杀菌 缓蚀 ozone,evaporative cooling air conditioning,circulating water,scale inhibition,bactericidal,corrosion inhibition
  • 相关文献

参考文献6

二级参考文献21

  • 1陈颖敏,赵英,李滨.臭氧处理循环冷却水[J].电力环境保护,1995,11(4):52-54. 被引量:2
  • 2王业耀,王占生,卢醒.臭氧处理循环冷却水的研究与应用[J].现代化工,1995,15(8):9-12. 被引量:4
  • 3S.E.Mayes,Using Ozone for Water Treatment,ASHRAE Journal,May 1998:39-42
  • 4Humphery M F,et al.Cooling tower water conditioning study.JPL Pub,1979:79
  • 5Proyor A.51rt Annual Meeting,International Water Conference,Pittsburgh,PA,1990:188
  • 6Wofford G,et al.Industrial Water Treatment,1991(1):33
  • 7Baldwin L V,et al.46th Annual Meeting,International Water Conference,Pittsburgh,PA,1985:36
  • 8Paul R.Puckorius et al.,Why Evaporative Coolers Have Not Caused Legionnaires′Disease,ASHRAE Journal,Jan.,1995:29-33
  • 9李文融 曾坚.循环水处理手册[M].天津:天津科学技术出版杜,1990..
  • 10Gert Jan Bom.Robert Foster.et a1.绿色蒸发冷却空调技术.西安工程科技学院译.2003.