摘要 文章简要介绍了投弃式电导率、温度、深度剖面测量仪(XCTD)的定标原理,并对现行的两种定标方法—五点定标和三点定标方法进行了比较研究。指出:与五点定标相比,三点定标方法具有高效、快速的优点,更适于大批量生产的要求。 This paper briefly introduces the calibration theory of The Expendable Conductivity/Temperature/Depth (XCTD) profile measuring probe, and compares the two present calibration method-five and three point calibration method. The results indicat that comparing with five point calibration the three point calibration method is efficient and fast and is more suitable for XCTD' s batch process.
作者 武玉华
出处 《海洋技术》 2007年第2期14-16,共3页 Ocean Technology
基金 国家高技术研究发展计划(863)资助项目(2001AA632050)
关键词 XCTD探头 五点定标法 三点定标法 XCTD probe five point calibration method three point calibration method
  • 相关文献

参考文献3

  • 1George Baron,Daniel J Mendoza.A System for Calibration of Expendable Conductivity,Temperature,And Depth (XCTD) Probes.OCEANS,1984,16:210-213.
  • 2Keisuke Mizuno,Tomowo Watanabe.Preliminary Results of in-situ XCTD/CTD Comparison Test.Journal of Oceanography,1998,54:373-380.
  • 3Alexander Sy,Darren Wright.XBT/XCTD Standard Test Procedures for Reliability and Performance Tests of Expendable Probes at Sea.3rd Session of JCOMM Ship-of-Opportunity Implementation Panel,2000.