摘要 目的研究一种新型非热等离子体空气净化器并观察其杀菌效果。方法采用电晕放电反应器和空气微生物采样器法进行了消毒器研制和杀菌效果评价。结果利用电晕放电反应器研制出循环风量达到1000m3/h的柜式非热等离子体空气净化器。在高污染室内启动该非热等离子体空气净化器运行30min,对室内空气中自然菌除菌率达89.9%;运行60min后,除菌率达到97.0%。经净化后的室内空气中自然菌总数由7739~24788cfu/m3平均下降至474cfu/m3。在较低污染室内启动该净化器运行30min,对室内空气中自然菌除菌率为77.2%。经净化后的室内自然菌数由116~540cfu/m3平均下降至79cfu/m3。结论非热等离子体空气净化器对室内空气中自然菌具有较好的除菌效果。 Objective To develope a new - type non - thermal plasma air purifier and observe its germicidal efficacy. Methods Corona discharge reactor and air microbe sampler were used to develope the disinfector and to evaluate its germicidal efficacy. Results Using corona discharge reactor, a cabinet - type non - thermal plasma air purifier with circulating air attaining 1000 m^3/h was developed. Operatibn of the non - thermal plasma air purifier for 30 min in a highly contaminated room removed 89.9% of the natural bacteria in indoor air and 97.0% of the bacteria were removed after operation for 60 min. The total natural bacterial count in indoor air decreased from 7739 - 24788 cfu/m^3 to 474 cfu/m~ in average after purification of the air. Operation of the air purifier for 30 min in a relatively lightly contaminated room removed 77.2% of the natural bacteria in indoor air. After air purification, the natural bacteria count in indoor air decreased from 116 - 540 cfu/m^3 to 79 cfu/m^3 in average. Conclusions The non - thermal plasma air purifier has relatively good efficacy in removing natural bacteria in indoor air.
出处 《中国消毒学杂志》 CAS 北大核心 2007年第5期441-443,共3页 Chinese Journal of Disinfection
基金 国家自然科学基金(50208005) 辽宁省高等学校优秀人才资助计划(RC-05-08)资助
关键词 非热等离子体 空气净化器 电晕放电 除菌效果 non - thermal plasma air purifier corona disicharge bacteria - removing efficacy
  • 相关文献

参考文献9

  • 1朱益民.一种非热放电和光催化协同净化污染空气的装置[P].中国专利:03202958.6;2004:9-22.
  • 2朱益民,孔祥鹏,陈海丰,宿鹏浩,孙培廷,张曼霞.针阵列对板电晕放电捕集微细颗粒物研究[J].北京理工大学学报,2005,25(z1):137-140. 被引量:2
  • 3朱益民,孔祥鹏,张卓然,张曼霞,郑丛龙.针阵列对板电晕放电对副流感病毒灭活的研究[J].北京理工大学学报,2005,25(z1):165-168. 被引量:2
  • 4Laroussi M.Sterilization of contaminated matter with an atmospheric pressure plasma[J].IEEE Trans Plasma Science,1996;24:1188.
  • 5Yamamoto M,Nishioda M,Sadakata M.Sterilization using a corona discharge with HO droplets and examination of effective species[J].Plasma Chemistry,2001; Ⅱ:743.
  • 6Kuzmichev AI,Soloshenko IA,Tsiolko VV,et al.Feature of sterilization by different type of atmospheric pressure discharges[J].High Pressure Low Temperature Plasma Chemistry,2001; Ⅱ:402.
  • 7朱晓波,陈家森,李祥,叶士璟.电晕放电致使微生物失活的机理研究[J].华东师范大学学报(自然科学版),2000(3):62-67. 被引量:2
  • 8Mendis DA,Rosenberg M,Azam F.A note on the possible electrostatic disruption of bacteria[J].IEEE Trans.Plasma Science,2000; 28:1304.
  • 9刘万红,叶士景,朱晓波,陈家森.微生物的电晕失活效应研究[J].生物物理学报,1998,14(1):150-154. 被引量:13

二级参考文献18

  • 1陈家森,叶士璟,陈树德,叶永青,吕凤俊.电场对水结构的影响──电场处理水的应用机理研究[J].物理,1995,24(7):424-428. 被引量:45
  • 2[3]Roberts P, Hope A. Virus inactivation by high intensity broad spectrum pulsed light [J]. Journal of Virological Methods, 2003, 110:61 -65.
  • 3[4]Shechmeister I L. Sterilisation by ultraviolet irradiation: Disinfection, sterilisation and preservation (3rd edition) [M].Philadelphia, USA: Lea and Febiger, 1983.106- 124.
  • 4[1]lto T, Kubota T, Zukeran A, et al. Collection characteristics of submicron particles on electrostatic precipitator[J]. The Journal of the Institute of Electrical Installation Engineers of Japan, 1995, 15 (2): 113-120.
  • 5[3]Dumitran L M, Blanchard D, Atten P, et al. Estimate of effective migration velocity of fine particles from fractional efficiency measurements in an electrostatic precipitator[J].ConfRec IAS Annu Meet, 2000, 1: 559-562.
  • 6[4]Chandra A. Investigations on electrostatic precipitator: A case study[J]. Conf Rec IAS Annu Meet, 1998, 3: 1947-1952.
  • 7[5]Brocilo D, Podlinski J, Dekowski J, et al. Electrohydrodynamic flow patterns in a wide spacing spike-plate electrostatic precipitators under negative coronas [A].Recent Developments in Applied Electrostatics[C]. Oxford.UK: Elsevier, 2004. 100-103.
  • 8[6]Okubo M, Yamamoto T, Kuroki T. Electric air cleaner composed of non-thermal plasma reactor and electrostatic precipitator[J]. Conf Rec IAS Annu Meet, 1999, 3: 1483-1488.
  • 9[6]Tree J A, Adams M R, Lees D N. Virus inactivation during disinfection of wastewater by chlorination and UV irradiation and the efficacy of F+ bacteriophage as a ‘Viral Indicator'[J]. Wat Sci. Tech, 1997, 35: 227-232.
  • 10[10]Goldmann D A. Transmission of viral respiratory infections in the home[J]. Pediatr, Nfect, Dis, J, 2000,10(Suppl): 97- 102.

共引文献14

同被引文献6

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部