期刊文献+

杜拉纤维对混凝土中钢筋腐蚀性能的影响

Influences of Dura fiber on corrosion of reinforcing bar in concrete
下载PDF
导出
摘要 用钢筋腐蚀失重率和半电池电位两个参数探讨了杜拉纤维掺量对钢筋混凝土中钢筋腐蚀的影响.室内试验结果表明,随杜拉纤维掺量的增加,钢筋腐蚀失重率降低、钢筋半电池电位增加.在钢筋混凝土中适量掺入杜拉纤维能有效地抑制钢筋腐蚀. The influences of admixture of Dura fiber on corrosion of reinforcing bar in concrete are discussed by using the parameters of corrosion weightless rates and half cell potential. Results of indoor laboratory tests show that the corrosion weightless rates decrease and the half cell potential increases with increase of dosage of Dura fiber. It is shown that adding Dura fiber into reinforced concrete will raise anti-corrosion behavior of the reinforcing bar.
出处 《水利水运工程学报》 CSCD 北大核心 2007年第3期70-72,共3页 Hydro-Science and Engineering
关键词 聚丙烯纤维 掺量 钢筋腐蚀失重率 钢筋半电池电位 钢筋混凝土 polynomial fiber dosage corrosion weightless rates of reinforcing bar half cell potential of reinforcing bar reinforced concrete
  • 相关文献

参考文献3

  • 1GBJ82-85.普通混凝土长期性能和耐久性能试验方法[S].[S].,..
  • 2余海龙.阻锈剂对碳化引起的钢筋腐蚀的阻锈效果研究[D].北京:中国建筑材料科学研究院,2003.
  • 3吴建华,赵永韬.钢筋混凝土的腐蚀监测/检测[J].腐蚀与防护,2003,24(10):421-427. 被引量:29

二级参考文献22

  • 1..http://www. force. dk/gb/default, htm[EB/OL].,.
  • 2Vladimir Ziviea. Utilisation of electrical resistance method for the evaluation of the state of steel reinforcement in concrete and the rate of its corrosion[J].Construction and Building Materials, 2000, 14:351-358.
  • 3Li X M, Chen W M, Zhu Y, et al. Monitoring the corrosion of steel in reinforced concrete using optical waveguide methods[J]. Proceeding of SHE, 2000,3986: 172-179.
  • 4Cairong Hu, Aaron Benally, Tobias Case, et al. Influence of chloride in mortar made of portland cement types Ⅱ ,Ⅲ and Ⅳ on the near-field microwave reflection properties[J]. Proceeding of SPIE, 2000,4129: 31-38.
  • 5Polder Bob B. Test methods for on site measurement of resistivity of concrete-a RILEM TC-154 technical recommendation[J]. Construction and Building Materials, 2001, 15: 125-131.
  • 6Rengaswamy Srinivasan, et al. Embedded micro-sensor for monitoring pH in concrete structure[J]. Proceeding of SPIE, 2000, 3988: 40-44.
  • 7Kelly R G, Jones Stephen H. Development of an embeddable microinstrument for corrosivity monitoringin concrete[C]. PB99-160210.
  • 8Elsener B. Half-cell potential mapping to assess repair work on RC structureD]. Construction and Building Materials, 2001, 15: 133-139.
  • 9Dubravka Bjegovic, Dunja Mikulic, Dalibor ekulic, Non-destructive corrosion rate monitoring for reinforced concrete structures [DB/OL].http://www. ndt. net/article/wcndt00/general/aipnd.htm.
  • 10BS7361 - 1991, Cathodic Protection, Part I. Code of Practice for Land and Marine Applications[S]. 50.

共引文献91

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部