期刊文献+

基于NiosII处理器的非金属超声检测分析仪 被引量:2

Nonmental Ultrasonic Detector Based on NiosII Processor
下载PDF
导出
摘要 介绍了非金属超声检测仪的软硬件设计方法。该仪器以EP2C20系列FPGA芯片为核心,通过在FPGA中加载NiosII软核处理器和其他外围接口电路,配合高精度数据采集系统、TFT液晶显示模块等设计而成。该仪器集超声波发射、同步接收、声参量自动检测、数据分析处理、结果实时显示、数据存储与输出等功能于一身,为数据的进一步分析处理和实现超声检测的图像化、智能化、自动化奠定了良好的基础。 The design of a nonmental ultrasonic detector was introduced. The detector was based on EP2C20 series FPGA chip, through adding NieslI soft processor and other interfaces to FPGA , equipped with high precision data collection system and TFT LCD module and so on. The system was constituted. It including ultrasonic eradiating,receive sychrononsly, audio parameter detecting automatically, data analyse and process, display result timely, data storage and data output circuits. For the developing of imaging, intelligent and automation of ultrasonictesting ,a very good foundation is established by the system.
出处 《仪表技术与传感器》 CSCD 北大核心 2007年第7期10-12,共3页 Instrument Technique and Sensor
关键词 NiosⅡ处理器 可编程片上系统 超声波 测桩 NiesⅡ processor SOPC Ultrasonic wave measuring benchmark
  • 相关文献

参考文献2

共引文献5

同被引文献18

  • 1梁浩,王亚平.基于NIOSⅡ的PWM控制器IP核的设计[J].包头职业技术学院学报,2010,11(3):5-7. 被引量:3
  • 2马胜前.阻抗谱测量系统的设计[J].传感器与微系统,2006,25(10):51-53. 被引量:4
  • 3KAPPES T, HAUSER P C. Electrochemical detection methods in capillary electrophoresis and applications to inorganic species. Journal of Chromatography A( S0021 9673 ), 1999,834:89 - 101.
  • 4ZEMANN A J, SCHNELL E, VOLGGER D, et al. Contactless conductivity detection for capillary electrophoresis. Anal. Chem. , 1998,70 : 563 - 567.
  • 5da SILVA J A F, do LAGO C F. An oscillometric detector for capillary electrophoresis. Anal. Chem. , 1998,70:4339 - 4343.
  • 6TANYANYIWA J, HAUSER P C. High -voltage capacitively coupled contactless conductivity detection for microchip capillary electrophoresis. Anal Chem ,2002,74:6378 - 6382.
  • 7LICHTENBERG J, de ROOIJ N F, VERPOORTE E. A microchip electrophoresis system with integrated in - plane electrodes for contactless conductivity detection. Electrophoresis,2002,23 : 3769 - 3780.
  • 8CHEN Y, YANG P, CHEN G,et al. Electrophoresis microchips with sharp inlet tips, for contactless conductivity detection, fabricated by in - situ surface polymerization. Anal Bioanal Chem,2006,384:683 - 691.
  • 9ALTERA, NiosII Custom Instruction User Guide [ EB/OL ], www. altera. com,2005.
  • 10ALTERA. FFI" MegaCore Function User Guide[ EB/OL]. www. altera. com,2005.

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部