摘要 首次将等离子体作为敏感元件应用于微机械陀螺仪中,取代目前微机械陀螺仪中所采用的固体、液体或气体等元件。利用气体放电产生的等离子体朗缪尔流效应来使敏感元件产生一定速度的运动,不需另外的驱动元件。介绍了等离子体朗缪尔流效应,探讨了应用朗缪尔流效应的新型微机械陀螺仪的原理,根据Langmuir-Drugvesteyn理论推算朗缪尔流速度可达到6 m/s,给出了该新型微机械陀螺仪的微加工与封装方案和工艺参数优化试验系统。 Hasma as sensitive component in micro mechanical gyro was applied for the first time,take the place of solid, liquid or pneumatic components. Plasma Langmuir flow effect produced by gas discharge was used to make sensitive component move at a certain velocity without further drive part. The plasma Langmuir flow effect was introduced, and the fundamental of novel micro mechanical gyro using Langmuir flow effect was discussed. The calculated Langmuuir flow velocity is 6 m/s according to Langmuir-Drugvesteyn theory. The micro machining and package method of this novel micro mechanical gyro and process parameters optimize experimental system were also presented.
机构地区 华中科技大学
出处 《仪表技术与传感器》 CSCD 北大核心 2007年第7期20-22,共3页 Instrument Technique and Sensor
基金 国家自然科学基金(50545012) 国家"八六三"计划MEMS专项基金(2005AA404260)
关键词 等离子体 朗缪尔流效应 陀螺仪 plasma Langmnir flow effect gyroscopes
  • 相关文献

参考文献4

二级参考文献16

  • 1刘斌,徐电,王新中,陈抗生.石英晶振真空传感器及真空计的研制[J].真空电子技术,1995,8(5):17-20. 被引量:12
  • 2黄天戍,陈苒菁.石英晶振频率测试系统的研究与开发[J].中国仪器仪表,2005(10):83-85. 被引量:7
  • 3郭秀中,陀螺仪理论及应用,1987年
  • 4Rong Zhu, Yan Su, Henggao Ding. A MEMS Hybrid Inertial Sensor Based on Convection Heat Transfer[C]//The 13th International Conference on Solid-State Sensors. Actuators and Microsystems,seoul,Korea. 2005, June 5-9. 114-116.
  • 5Leung A, M, Jones J, Czyzewska E, Chen J, Woods B. Micromachined Accelerometer Based on Convection Heat Transfer[C]//Proceedings of the IEEE Micro Electro Mechanical Systems (MEMS), Heidelberg, Germany, 1998, January 25-29. 627-630.
  • 6Crescini D, Marioli D. An Inclinometer Based on Free Convective Motion of A Heated Air Mass[C]//Sensors for Industry Conference IEEE, New Orleans, Louisians, USA, 2004, January 27-29. 11-15.
  • 7Rong Zhu, Henggao Ding ,Yan Su, ZhaoYing Zhou. Micromachined Gas Inertial Sensor Based on Convection Heat Transfer[J]. Sensors and Actuators. 2005.
  • 8HIRATA, KOKUBUN K, ONO M, et al. Nakayama size effect of a quartz oscillator on its characteristics as a friction vacuum gauge. J. Vac. Sci. Technol, 1985,5(6) : 1742 - 1745.
  • 9ONO M, HIRATA M, KOKUBUN K, et al. Design and performance of a quartz oscillator vacuum gauge with a controller. J. Vac. Sci. Technol, 1985,A 3(3) : 1746 - 1749.
  • 10ONO M, HIRATA M, KOKUBUN K, et al. Quartz friction vacuum gauge for pressure J. Vac. Sci. Technol, 1986, A4 ( 3 ) : 1728 - 1731.

共引文献16