摘要
通过对炮长微光指挥镜C2组试验中质量问题的解剖,分析了气密性检查方法的缺陷,特殊结构的光学产品气密性检查和水密性检查不能等效代替。
By the dissecting of the guality in testing low level light commanding instrument C 2 group of chief artillermen, the defects in existing tightness testing method is analyzed, pointing out that the air tightness testing and the water tightness testing of optical products with special structure are not equivalent and can not be sub stituted. The measures for up grading the tightness are also proposed.
出处
《光学技术》
CAS
CSCD
1997年第1期46-48,共3页
Optical Technique