期刊文献+

大范围扩散加权成像在3.0T MR应用的初步研究 被引量:12

Large field diffusion weighted imaging on 3.0T MR: initial study
下载PDF
导出
摘要 目的评价3.0T磁共振大范围扩散加权成像(DWI)的可行性和可重复性。方法在3.0T磁共振上采用STIR-DWI序列对10例正常志愿者进行扫描。为研究大范围DWI的可重复性,1周内对志愿者进行2次大范围STIR-DWI扫描,扫描范围从头到小腿,共1664mm,b=800s/mm2。评价图像的可读性,记录严重变形和出现伪影的部位。应用Functool2软件进行后处理,测量部分正常组织的ADC值,应用配对t检验比较两次大范围DWI上所测组织ADC值的一致性。结果大范围DWI仅在颈部处有轻微的变形和伪影。统计结果表明两次扫描所测组织ADC值一致性较好。结论在3.0TMR扫描仪上行大范围DWI扫描是可行的,且重复性较好,可用于开展临床研究。  Objective To evaluate the feasibility and reproducibility of large field diffusion weighted imaging (DWI) on 3.0T MRI. Methods Ten healthy young volunteers were included in this study. In order to evaluate the reproducibility of large field DWI, large field short TI inversion recovery (STIR) DWI were performed twice in healthy volunteers within one week. The scanning extent was 1664 mm from head to leg with b value of 800 s/mm2. The readability of images was evaluated, serious distortion and artifact locations were recorded. Images were postprocessed with Functool 2 software, and apparent diffusion coefficients (ADCs) of partial normal tissues were measured. Paired sample t test was used for statistical analysis. Results Only slight distorsion and ghosting artifacts were found in junction area of neck and thorax on large field DWI. There was good agreement between the mean ADCs measured by two different DWI examinations. Conclusion Large field DWI performed on 3.0T MR scanner is feasible and reproducible.
出处 《中国医学影像技术》 CSCD 北大核心 2007年第8期1245-1247,共3页 Chinese Journal of Medical Imaging Technology
关键词 扩散加权 磁共振成像 Diffusion weighted imaging Magnetic resonance imaging
  • 相关文献

参考文献6

  • 1张春燕,王霄英,蒋学祥.扩散加权成像在全身肿瘤性病变中的应用[J].中国医学影像技术,2006,22(11):1762-1766. 被引量:17
  • 2Takahara T,Imai Y,Yamashita T,et al.Diffusion weighted whole body imaging with background body signal suppression(DWIBS):technique improvement using free breathing,STIR and high resolution 3D display[J].Radiation Medicine,2004,22(4):275-282.
  • 3Eustace S,Tello R,De CV,et al.A comparison of whole-body turbo STIR MR imaging and planar 99Tcm-methylene diphosphonate scintigraphy in the examination of patients with suspected skeletal metastases[J].AJR,1997,169(6):1655-1661.
  • 4Eustace S,Walker R,Blake M,et al.Whole-body MR imaging.Practical issues,clinical applications,and future directions[J].Magn Reson Imaging Clin N Am,1999,7(2):209-236.
  • 5Schlemmer HP,Schafer J,Pfannenberg C,et al.Fast whole-body assessment of metastatic diseases using a novel magnetic resonance imaging system:initial experience[J].Invest Radiol,2005,40(2):64-71.
  • 6孙非 曹光 李硕 等.全身弥散技术简介.GE医疗,2006,4:10-11.

二级参考文献1

共引文献16

同被引文献97

引证文献12

二级引证文献73

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部