期刊文献+

无源效率刻度技术研究进展及应用概况 被引量:44

Research and Application of Souceless Efficiency Calibration Technic
下载PDF
导出
摘要 介绍了HPGe探测器无源效率刻度技术的研究进展及国内外应用概况,简单描述无源效率刻度软件ISOCS和LabSOCS的原理及验证工作,讨论了有源效率刻度和无源效率刻度的优缺点,最后提出无源效率刻度方法是一种快速、准确的刻度方法。 An introduction is given on the research and application of HPGe detectors' souceless efficiency calibration. The ISOCS and LabSOCS are also described, then compare the advantage and disadvantage of the sourceless and source-based efficiency calibriaton, in the end we indicate that sourceless efficiency calibration is a fast and accurate method.
作者 付杰 徐翠华
出处 《核电子学与探测技术》 CAS CSCD 北大核心 2007年第4期799-804,共6页 Nuclear Electronics & Detection Technology
关键词 无源效率刻度 蒙特卡罗 ISoCS LabSoCS HPGe探测器刻度 souceless efficiency calibration Montr Carlo ISOCS LabSoCS calibration of HPC, e detectors
  • 相关文献

参考文献17

  • 1朱文凯,陈军,熊建平,陈坤,陈益军.ISOCS系统无源效率刻度测量方法的准确性检验[J].核电子学与探测技术,2005,25(3):287-290. 被引量:33
  • 2肖雪夫.就地 HPGe γ 谱仪校准系数的蒙特卡罗计算[J].辐射防护,1999,19(1):43-57. 被引量:10
  • 3徐翠华,张庆,周强,任天山,耿秀生.HPGe探测效率和符合相加修正系数的蒙特卡罗计算[J].中国辐射卫生,2004,13(2):92-96. 被引量:4
  • 4Mark DowdalL Practicable Monte Carlo Calibration of HPGe Detectors for Environmental Measurements. Norway.
  • 5J. Boson , et al. Improving Calibration of HPGe Detectors for In Situ Measurernents-a Comparison of Semiempirical and Monte Carlo Methods. Sweden.
  • 6复旦大学 清华大学 北京大学.原子核物理实验方法[M].北京:原子能出版社,1997.93-96,109-117,301-304.
  • 7GB/T16145-1995.生物样品中放射性核素的τ能谱分析方法[S].
  • 8Canberra. User's Manual of Model S573 ISOCS Calibration Software[M]. USA, 2002.
  • 9J. F. Briesmeister. MCNP-A general purpose Monte Carlo N-Particle Transport code, Version 4A [R]. California: Radiation Shielding Information Center, Oak Ridge, 1993.
  • 10R. Venkataraman et al. Validation of In Situ Object Counting System (ISOCS) Mathematical Efficiency Calibration Software[C]. 9^th Symposium on Radiation Measurements and Applications. USA, 1998.

二级参考文献32

  • 1向长兴.一组实用γ谱分析效率刻度曲线[J].核电子学与探测技术,1994,14(6):363-366. 被引量:9
  • 2GB/T 16140-1995,水中放射性核素的γ能谱分析方法[S].
  • 3郝润龙,谭金波.JJG578-94锗γ谱仪体源活度测量装置检定规程[S].
  • 4何宗慧.近距离测量时Ge(Li)探测器的峰效率刻度和符合相加修正[J].辐射防护,1986,6(6):431-431.
  • 5Debertin K. And Schotzig U. Coincidence summing corrections in Ge(Li)-spectrometry at low source to detector distances[J]. Nuclear Instruments and Methods. 1979 158,471.
  • 6Ashrafi S, Likar A, Vidmar T. Precise modeling of a coaxial HPGe detector[J]. Nuclear Instruments and Methods, 1999,438,421.
  • 7Gerhard Haase, David Tait, Arnold Wiechen. Application of a new Monte Carlo method for determination of summation and self -attenuation corrections in gamma spectrometry [J]. Nuclear Instruments and Methods, 1993,336, 206.
  • 8Korun M, Likar A, Vidmar T. Monte-Carlo calculation of the spatial dependence of the coaxial HPG e detector efficiency for point sources[J]. Nuclear Instruments and Methods,1997,390,203.
  • 9Marc Decombaz,Jean Jacques Gostely, Jean Pascal Laedermann.Coincedence summing corrections for extended sources in gamma -ray spectrometry using Monte Carlo simulation [J]. Nuclear Instruments and Methods,1992, 312,152.
  • 10Arnold D, Wershofen H. Specific calibration problems for gammaspectrometric measurements of low-level radioactivity in environmental samples, Methods and applications of low- level radioavtivity measuements[J]. Proceeding, 1997,170,1139-142.

共引文献98

同被引文献263

引证文献44

二级引证文献68

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部