根据有关设计规范,结合目前产品情况,介绍了消防设备配电回路的典型接线方案,讨论了由传统分立元器件组成的消防设备配电回路主要设备的选择,如低压断路器、交流接触器、热继电器、自动转换开关。希望对全国的电力设计者提供有益的参考。
Based on related design code and product actuality, the typical connection scheme of power distribution circuit of fire equipment was introduced. Selecting main components, such as low voltage breaker, alternating current contactor, thermal overload relay, automatic transfer switch for power distribution circuit of fire equipment which was composed of conventional separate components was discussed to provide a helpful reference for power designer in China.
出处
《低压电器》
北大核心
2007年第16期24-27,47,共5页
Low Voltage Apparatus
关键词
高层民用建筑
消防设备
配电回路
设备选择
低压断路器
交流接触器
热继电器
自动转换开关
high residential building
fire equipment
power distribution circuit
equipment selection
low voltage breaker
alternating current contactor
thermal overload relay
automatic transfer switch