摘要 目的 对比分析Vita Classical比色片颈部、中部、切部色度值,探讨同名比色片这3个部位颜色是否一致.方法 利用MINOLTA CR-321接触式色差计,以CIE-1976-L*a*b*表色系统,分别测定5套Vita Classical比色片颈部、中部、切部1/3色度值,并进行组间色差对比分析.结果 各部位色差均在1.70~4.25之间;C4比色片的切部与中部ΔE<1.7.16个Vita Classical比色片颈部与中部,切部与中部,颈部与切部之间的平均色差分别是4.38,2.13,5.19,ΔE>1.7.结论 Vita Classical 16个比色片,在比色的过程中,不能只进行中部或局部的颜色比较.局部色不能反映该比色片完整颜色状况,各部位的颜色均存在差异. Objective To investigate whether the color of Vita Classical shade guide in 3 different positions is consistent by comparing and analyzing the chroma of shade guide(Vim Classical) in cervical, middle and incisal positions. Methods The chroma of 5 sets of Vita Classical shade guide in cervical, middle and incisal positions was tested using MINOLTA CR-321 contacted colorimeter(D65 respectively) and the color was measured by CIE-1976-L * a * b * system. The differences were contrasted and analyzed. Results The color differences in the three positions were between 1.70 and 4.25; the color differences between incisal and middle positions of C4 were smaller than 1.7; the mean color differences between cervical and middle positions, incisal and middle positions, cervical and incisal positions of 16 shade guides(Vita Classical) were 4.38, 2.13 and 5.19, respectively(△F. 〉 1.7). Conclusions In the process of color matching, it is unfit to contrast the color only in the middle of the tooth. The color of middle part cannot represent the whole color of the shade guide.
出处 《口腔医学》 CAS 2007年第8期409-410,415,共3页 Stomatology
关键词 比色板 色差 色度 shade guide color difference chroma
  • 相关文献

参考文献8

  • 1Wee AG,Monaghan P,Johnston WM.Variation in color between intended matched shade and fabricated shade of dental porcelain[J].J Prosthet Dent,2002,87(6):657-666.
  • 2吴华,王新知,高承志.107例烤瓷冠与所选Vita比色板色样的色度值比较[J].现代口腔医学杂志,2003,17(2):143-144. 被引量:11
  • 3Jorgenson MW.Spectrophotomertic study of five porcelain shades relative to the dimensions of color,porcelain thickness,and repeated firings[J].Prosthet Dent,1979,42(1):96-112.
  • 4Seghi RR,Hewlett ER,Kim J.Visual and instrumental colorimetric assessments of small color differences on translucent dental porcelain[J].J Dent Res,1989,68(12):176-183.
  • 5吴效民,宋世卿.Vita比色板色度分析[J].中华口腔医学杂志,1996,31(4):227-229. 被引量:80
  • 6扬治良.实验心理学[M].杭州:浙江教育出版社,2002:310.
  • 7黄常伟,程辉,卢友光,郑明.牙科比色板颜色的计算机分析[J].福建医科大学学报,2000,34(3):274-276. 被引量:2
  • 8Ishikawa-Nagai S,Sawafuji F,Tsuchitoi H,et al.Using a compute color-matching system in color reproduction of porcelain restoration.Part 2:color reproduction of stratiform-layered porcelain samples[J].Int J Prosthodont,1993,6(6):522-538.

二级参考文献7

共引文献89

同被引文献66

引证文献3

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部