期刊文献+

微波消解-石墨炉原子吸收光谱法测定鱼粉中的镉和铬 被引量:5

Determination of cadmium and chromium in fish meal by microwave digestion-graphite furnance atomic absorption spectrometry
下载PDF
导出
摘要 采用微波消解技术处理样品,用石墨炉原子吸收光谱法测定,对消解溶剂和微波条件进行了优化,研究了石墨炉原子吸收法的测定条件。结果表明,以HNO3+HClO4+H2O2作为微波消解溶剂效果最佳,在基体改进剂NH4H2PO4和Pd(NO3)2存在下,可有效地消除基体的影响,建立了微波-石墨炉原子吸收光谱法测定鱼粉中镉(Cd)和铬(Cr)的方法,Cd和Cr检出限分别为0.17ng/mL和0.46ng/mL;回收率分别为88.2%~94.1%(RSD:2.7%,n=6)、91.7%~106.2%(RSD:6.6%,n=6)。 A method using microwave digestion technique was developed for the determination of cadmium (Cd) and chromium(Cr) in fish meal by graphite furnace atomic absorption spectrometry(GFAAS),Digestion solvents were discussed for sample preparation by microwave digestion technique.The optimum condition of determination by GFAAS was studied in presence of NH4H2PO4 and Pd (NO3)2 matrix modifier.The detection limits of Cd and Cr were 0.17 ng/mL and 0,46 ng/ mL,respectively.The recoveries of Cd and Cr were 88,2 % - 94.1% (RSD:2.7 % ,n=6)and 91.7 % - 106.2 % (RSD: 6.6 %, n=6), respectively.
出处 《中国饲料》 北大核心 2007年第16期34-37,共4页 China Feed
关键词 鱼粉 石墨炉原子吸收光谱法 微波消解 fish meal GFAAS microwave digestion technique cadmium chromium
  • 相关文献

参考文献6

二级参考文献16

共引文献39

同被引文献92

引证文献5

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部