静脉肾盂造影压迫器的改进与临床应用研究——附压迫点及压迫时机的确定与选择 被引量:1

Intravenous Pyelography Compressor Improvement and Clinical Practice Research——Attach the Oppression Point and the Oppression Opportunity Determination and the Choice
下载PDF
导出
摘要 目的:探讨静脉肾盂造影压迫器的改进和压迫点及压迫时机的选择,提高造影成功率和尿路显示质量。材料与方法:废弃了传统的气囊多头腹带压迫器,制作了新式圆弧型压迫器,改进的压迫器腹带上有标尺刻度,不但起压迫和固定作用,同时又起到了对压力的量化控制作用;同时对腹部压迫点和压迫时机做了正确选择,即八字行压迫器垫应置于"两髂前上棘连线中点的两侧"作为正确压迫点;其压迫时机是,造影剂注射完毕后3分钟时开始对"腹部压迫点"实施压迫;其加压量化指标为注射造影剂前"预加压"的量化数值。结果:应用改进方法行静脉肾盂造影60例,无1例失败,造影成功率达到100%,均达到诊断要求。结论:造影效果提示我们,只有改进压迫器并将压迫器置于正确的压迫点再加上恰当的压力和压迫时机,才能取得满意的静脉肾盂造影效果。 Purpose: The discussion intravenous pyelography compressor inprovement and the oppression opportunity choice, enhances the pyelography success ratio and the urine road display quality. Materials and Methods: Has abandoned traditional aero cyst many abdominal binder compressor, has fabrication the new are form compressor, the improvement compressor abdominal bandage on has the rod scale division, not only the oppression and the damping action, simuhaneously responsible the pressure quantification control action; Meanwhile and the oppression opportunity has made the correct choice to tie abdomen oppression, namely the caret shaped line of oppression pad should "set to two spina iliaca anterior superior center point two sides" took the correct oppression spot, its oppression opportunity is, after the intravenous pyelography contrast medium injection finished when 3 minutes starts to "the abdomen oppression point" the implementation oppression, it pressurizes the quantification target wants for the injection contrast medium in front of to pressurize the quantification value. Results: Using the improvement method good intravenous pyelograpby 60 examples, does not have an example defeat , the pyelography success ratio achieves 100%, whole to achieve the diagnosis requirements. Conclusion: The intavenous pyelography effect prompts us, will only have the improvement oppression and the compressor standing correct oppression spot adds on the appropriate pressrre and the oppression opportunity again, will be able to obtain satis- factory the intravenous pyelography result.
出处 《现代医用影像学》 2007年第4期152-154,共3页 Modern Medical Imageology
关键词 静脉肾盂造影 压迫器 压迫点 压迫时机 Intravenous pyelography Compressor Oppression point Oppression opportunity
  • 相关文献

参考文献6

  • 1刘琴珍.静脉肾盂造影腹部加压力的选择[J].中华放射学杂志,1982,16(4):302-302.
  • 2季若村.中等剂量静脉尿路造影术[J].中华放射学杂志,1983,17(4):304-304.
  • 3聂洪奎等.低张静脉造影术介绍[J].中华放射学杂志,1985,19(2):225-225.
  • 4林宏建.静脉肾盂造影中的腹带加压法[J].中华中西医杂志,2004,5(16):20-20.
  • 5陈立丰等.中剂量不加腹压静脉尿路造影[J].实用放射学杂志,1985,1(2):81-81.
  • 6陈引璋.在腹部不用压迫下静脉肾盂造影[J].实用放射学杂志,1990,6(1):37-37.

同被引文献9

  • 1施建明.静脉尿路造影压迫器.北京:中华人民共和国国家知识产权局(实用新型),2010,1.
  • 2Nawfel RD,Judy PF,Schleipman AR,et al. Patient radiation dose at CT urography and conventional urography. Radiology,2004,232:126.
  • 3张沛.充气式肾盂造影压迫器.北京:中华人民共和国国家知识产权局(实用新型),1987.
  • 4张凯,于建波,李彩霞,等.静脉肾盂造影压迫器.北京:中华人民共和国国家知识产权局(实用新型),2006.
  • 5余建华,刘汉生,魏丛全,等.肾盂造影自动压迫器.北京:中华人民共和国国家知识产权局(实刑新型),2001.
  • 6Van Der Molen AJ,Cowan NC, Mueller Lisse UG,et al. CT urography. definition, indications and techniques A guideline for clinical practice. Eur Radiol,2008,18:4.
  • 7上海市卫生局 中华医学会上海分会编著.医学影像学诊疗常规[M].上海:上海科学技术出版社,1999.489.
  • 8于浩.CT尿路造影与静脉尿路造影在泌尿系疾病诊断中的比较[J].中国现代医生,2010,48(4):101-102. 被引量:10
  • 9方向明,胡晓云,胡春洪,陈宏伟,崔磊,庄启湘.静脉尿路造影联合CT平扫对上尿路病变的诊断价值[J].临床放射学杂志,2010,29(3):358-361. 被引量:3

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部