谏壁发电厂2004年以后投运的6 kV 200 kW新型炉水泵,运行1年左右之后,其电机均发生了不同程度的故障。为查找故障点对炉水泵进行拆检,并进一步分析原因,以期对其它电厂总结检修经验起到借鉴作用。
A 6 kV 200 kW new type of boiler forced circulation pump was put into operation in 2004 in Jianbi Power Plant ,after one year' operation ,its motors all had experienced failure of certain degree. The pump was dismantled for inspection and further analysis. Such experience is expected to be used as reference for other power plant.
出处
《华北电力技术》
CAS
2007年第9期43-45,共3页
North China Electric Power
关键词
炉水泵
电机
故障原因
boiler pump
motor
cause of failure