摘要 目的:建立人血浆中罗红霉素的高压液相/质谱(HPLC-MS)测定方法。方法:采用Diamon- sil-C 18柱(200mm×4.6mm,5μm),流动相为甲醇(10mmol/L)醋酸铵缓冲液(pH=3.5)80:20,流速为1.0ml/min。用含内标(克拉霉素)的乙腈液沉淀蛋白,离心后取上清液进样,以质谱为检测手段,按内标法定量。结果:本法在0.05~10.0μg/mL范围内线性关系良好,批内RSD<1.96%,批间RSD<2.50%,批内RE<4.96%,批间RE<5.54%。结论:该方法灵敏度高,精密度和准确度好,适用于罗红霉素血药浓度的测定。 Objective: To establish a HPLC-MSmethod for determining the concentration ofroxithromycin in plasma. Methods: This assay is conducted on Diamonsil C 18 column(200 mm× 4.6 mm, 5 μm). The mobile phase consists of methanol(10 mmol/L)and ammonium acetate(pH=3.5)80:20, at the flow-rate of 1.0 ml/min. The plasma was treated with acetonitrile, which contains clarithromycin. After the centrifuge of this mixture, the supernatant was injected into the chromatographic system. This method adopts MS detectorand is based onthe internal standardto analyse quantitatively. Results: Roxithromycin has good linear relationship between 0.05- 10 μg/mL. Within-group and between-group precision expressed by relative standard deviation is less than 1.96% and 2.50%. Intra-group and inter-group accuracy expressed by RE is less than 4.96% and 5.54%. Conclusion: The method is highly sensitive, precise and accurate. It is applicable to the determination of roxithromycin inplasma.
出处 《抗感染药学》 2007年第3期108-111,共4页 Anti-infection Pharmacy
关键词 罗红霉素 血药浓度 高效液相/质谱 Roxithromycin plasma concentration HPLC-MS
  • 相关文献

参考文献6

二级参考文献22

  • 1汪泓,张全英,施爱民.HPLC法测定人血浆中罗红霉素的含量[J].抗感染药学,2005,2(1):25-26. 被引量:9
  • 2韩可勤,黄圣凯.生物等效性评价中数据对数变换后的一些统计问题[J].中国临床药理学杂志,1994,10(2):124-128. 被引量:35
  • 3陆红,李家泰,刘彦,关勇,吕媛.国产罗红霉素人体生物利用度研究[J].中国临床药理学杂志,1996,12(2):85-88. 被引量:11
  • 4中华人民共和国药典委员会.中华人民共和国药典,二部[M].北京:人民卫生出版社,1995.163.
  • 5[2]Nilsen OG, Aamo T, Zahlsen K, et al. Macrolide pharmacokinetics and dose scheduling of roxithromycin [J]. Diagn Microbiol Infect Dis. 1992, 15 (4 Suppl): 71S
  • 6[3]Fassbender M, Lode H, Schiller C, et al. Omparative pharmacokinetics of macrolide antibiotics and concentrations achieved in polymorphonuclear leukocytes and saliva [J]. ClinMicrobiol Infect. 1996, 1 (4): 235
  • 7[4]Macek J, Ptacek P. Determination of roxithromycin in human plasma by high-performance liquid chromatography with spectrophotometric detection [J]. J Chromatogr B Biomed Sci Appl. 1999, 723 (1~2): 233
  • 8Macek J , Placek P , Klima J. Determination of roxithroomycin in plasma by high- performance liquid chromatography with spectometric detection [J ] .J Chromatogr B Biomed Sci Appl , 1999,7(2) : 233.
  • 9Draisci R, Palleschi L, Ferretti E, et al. Confirmatory met macrolide residues in bovine tissues by micro- liquid chromatograpdem mass spectrometry [ J ] .J Chromatogr A, 2001,926(1) : 97.
  • 10陆红,中国临床药理学杂志,1996年,12卷,2期,65页

共引文献31

同被引文献5

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部