期刊文献+

可吸收固定材料治疗关节内骨折临床应用 被引量:1

Clinical analysis of intra-articular fracture treated with absorbable screws and rods
下载PDF
导出
摘要 目的:评价可吸收材料治疗关节内骨折的临床效果。方法:32例关节内骨折患者应用可吸收螺钉及固定棒[自身增强聚乙酯(self-reinforced polyglycolic acid,SR-PGA),自身增强聚丙酯(self reinforced poly-L-Lactic acid,SR-PLLA)]将骨折复位后固定,术后常规应用抗生素预防感染,行骨牵引或石膏外固定。结果:患者伤口均Ⅰ期愈合,关节内骨折1~3个月内均达到临床愈合,关节功能基本正常,无再移位、感染及局部积液。术后随访5~48个月,平均25个月,关节功能评价(AASO):优22例,良7例,可2例,差1例,优良率90.6%。结论:可吸收内固定材料是关节内骨折理想的内固定材料,能被完全吸收骨化。 Objective :To assess the curative effect of intra-articular fracture treated with absorbable screws and rods. Methods :32 patients with intra-articular fracture were treated by absorbable screws and rods made of self-reinforced polyglycolic acid(SR-PGA) and self-reinforced poly-L-Lacticacid (SR-PLLA).After operation ,the antibiotics were used to prevent infection. Skeletal traction and piaster external fixation were used too. Results:The wounds healed by first intention and the healing time of bone was 1~3 months.No dislocation,infection and local effusion occurred. The patients were followed up from 5 months to 48 months with an average of 25 months.Functional recovery was satisfactory.According to AASO articular function standard ,the results were excellent in 22cases,good in 7 cases,fair in 2 case,and poor in 1 case. The total excellent and good rate was 90.6%. Conclusion:Internal fixation of absorbable screws and rods, which can be absorbed and ossified completely,is a perfect procedure in treating intra-articular fracture.
出处 《现代医药卫生》 2007年第20期3018-3020,共3页 Journal of Modern Medicine & Health
关键词 关节内骨折 可吸收螺钉 内固定 Intra-articular fracture Absorbable screw and rod Internal fixation
  • 相关文献

参考文献7

  • 1Harness NG,Meals RA. The history of fracture fixation of the hand and wrist[J]. Clin Orthop Relat Res,2006,445:19.
  • 2Ito H,Matsuno T,Minami A. Fixation with poly-L-lactide screws in hip osteotomies[J]. Clin Orthop Relat Res ,2006,444: 169.
  • 3Kaukonen JP,Lamberg T,Korkala O,et al. Fixation of syndesmotic ruptures in 38 patients with a malleolar fracture: a randomized study comparing a metallic and a bioabsorbable screw[J]. J Orthop Trauma,2005,19(6) : 392.
  • 4Handolin L,Kiljunen V,Arnala I,et al. The effect of low intensity ultrasound and bioabsorbable self-reinforced poly-L-lactide screw fixation on bone in lateral malleolar fractures[J].Arch Orthop Trauma Surg,2005,125(5): 317.
  • 5Cox S,Mukherjee DP,Ogden AL,et al. Distal tibiofibular syndesmosis fixation: a cadaveric, simulated fracture stabilization study comparing bioabsorbable and metallic single screw fixation[J]. J Foot Ankle Surg, 2005,44(2) : 144.
  • 6Eppley BL. Use of resorbable plates and screws in pediatric facial fractures[J]. J Oral Maxillofac Surg,2005,63(3):385.
  • 7Cavusoglu T, Yavuzer R, Basterzi Y ,et al. Resorbable plate-screw systems:clinical applications[J]. Ulus Travma Acil Cerrahi Derg,2005, 11(1):43.

同被引文献10

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部