期刊文献+

眼膜组织厚度模型化及非接触式测量系统的研究 被引量:1

Research on Modeling of Human Ocular Tissue Layers' Thickness and Non-contact Ophthalmic Detection System
下载PDF
导出
摘要 设计了眼膜组织的模型,并根据眼膜组织的物理特性进行模型化。研制了一种基于光纤位移传感器的非接触式眼膜组织厚度检测系统。通过实验测得模型厚度为2.086mm,与实际厚度(2.5mm)有0.414mm误差。非接触式测量系统为眼膜组织厚度提供了一种新的有效测量手段。 The model of human ocular tissue layers was designed based on the physical features of ocular tissue layers. A non-contact ophthalmic detection system was designed using fiber-optical displacement sensor. Model thickness was tested. The result showed that the thickness of model was 2.086mm and had 0.414mm error with the real thickness. It is concluded that non-contact ophthalmic detection system offers a new efficient method for human ocular tissue layers thickness.
出处 《生物医学工程研究》 2007年第3期240-243,247,共5页 Journal Of Biomedical Engineering Research
关键词 非接触 共聚焦 光纤 眼球组织层厚度检测 模型化 Non-invasive Confocal Fiber-optics Detection of ocular tissue layers Model
  • 相关文献

参考文献7

二级参考文献30

  • 1王宁利,周文炳,叶天才,吴中耀,刘华.原发性闭角型青光眼的临床研究[J].中华眼科杂志,1995,31(2):133-136. 被引量:102
  • 2[1]Liu ZG, Andrew J, Pflugfelder SC, et al. Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system. Br J Ophthalmol, 1999,83:774
  • 3[4]Douthwaite WA, Matilla MT. The TMS-1 corneal topography measurement applied to calibrated ellipsoidal convex surfaces. Cornea, 1996,15:147
  • 4Marsich MW,Bullimore M.The repeatability of corneal thickness measures.Cornea,2000,19:792 -795.
  • 5Giasson C,Forthomme D.Comparison of central corneal thickness measurements between optical and ultrasound pachometers.Optom Vis Sci,1992,69:236-241.
  • 6Rufer F,Schroder A,Arvani MK,et al.Central and peripheral corneal pachymetry--standard evaluation with the Pentacam system.Klin Monatsbl Augenheilkd,2005,222:117-122.
  • 7Clare OD,Carole MC.Agreement and repeatability of Central Thickness Measurement in Normal Corneas Using Ultrasound Pachymetry and the OCULUS Pentacam.Cornea,2005,24:920-924.
  • 8杨文利,胡士敏,王景昭,王兰,郑邦和.眼内肿瘤的彩色超声多普勒诊断分析[J].中华眼科杂志,1997,33(4):272-276. 被引量:38
  • 9赖铭莹,王宁利,叶天才,陈秀琦,周文炳.超声生物显微镜在眼前段钝挫伤中初步应用[J].中国实用眼科杂志,1998,16(7):408-410. 被引量:21
  • 10何雷,庞秀琴,杨文利,王文伟.超声生物显微镜诊断眼前节微小异物[J].眼科,1998,7(3):146-149. 被引量:14