期刊文献+

Direct and Simultaneous Determination of Phenol, Hydroquinone and Nitrophenol at Boron-Doped Diamond Film Electrode 被引量:1

Direct and Simultaneous Determination of Phenol, Hydroquinone and Nitrophenol at Boron-Doped Diamond Film Electrode
原文传递
导出
摘要 The electrochemical characteristics of multi-component phenolic pollutants, such as phenol (Ph), hydroquinone (HQ) and 4-nitrophenol (4-NP), were investigated on boron-doped diamond (BDD) film electrode by differential pulse voltammetry (DPV) technique. A simple and feasible platform was accordingly established for the direct and simultaneous determination of these three phenolic pollutants. Results showed that, Ph, HQ and 4-NP gave obvious oxidation peaks on BDD electrode at the potential of 1.24, 0.76 and 1.52 V, respectively. Each of them displayed good linear relationship between their oxidation peak currents and their corresponding concentrations in a rather wide range coexisting with one or two of the other phenolic pollutants. The detection limits of Ph, HQ and 4-NP were estimated to be as low as 1.82×10^-6, 1.67×10^-6 and 1.44×10^-6 mol·L^-1, respectively. Therefore, a promising direct and simultaneous electrochemical determination method of multi-component phenolic pollutants in wastewater samples was constructed successfully on BDD electrode with advantages being rapid, simple, convenient, sensitive, in situ and inexpensive. The electrochemical characteristics of multi-component phenolic pollutants, such as phenol (Ph), hydroquinone (HQ) and 4-nitrophenol (4-NP), were investigated on boron-doped diamond (BDD) film electrode by differential pulse voltammetry (DPV) technique. A simple and feasible platform was accordingly established for the direct and simultaneous determination of these three phenolic pollutants. Results showed that, Ph, HQ and 4-NP gave obvious oxidation peaks on BDD electrode at the potential of 1.24, 0.76 and 1.52 V, respectively. Each of them displayed good linear relationship between their oxidation peak currents and their corresponding concentrations in a rather wide range coexisting with one or two of the other phenolic pollutants. The detection limits of Ph, HQ and 4-NP were estimated to be as low as 1.82×10^-6, 1.67×10^-6 and 1.44×10^-6 mol·L^-1, respectively. Therefore, a promising direct and simultaneous electrochemical determination method of multi-component phenolic pollutants in wastewater samples was constructed successfully on BDD electrode with advantages being rapid, simple, convenient, sensitive, in situ and inexpensive.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2007年第10期1445-1450,共6页 中国化学(英文版)
基金 Project supported by the National Natural Science Foundation of China (Nos. 20577035 and 50478106) and Nanometer Science Foundation of Shanghai (No. 0652nm030).
关键词 boron-doped diamond film electrode phenolic pollutant differential pulse voltammetry MULTI-COMPONENT simultaneous determination boron-doped diamond film electrode, phenolic pollutant, differential pulse voltammetry, multi-component, simultaneous determination
  • 相关文献

同被引文献5

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部