离子选择电极连续测定天然水中钾钠含量 被引量:3

Determination of potassium and sodium in natural water by ion selective electrode
下载PDF
导出
摘要 离子选择电极连续测定天然水中钾钠含量李运涛(西北轻工业学院化学工程系,陕西咸阳712000;作者,男,33岁,讲师)钾钠是天然水中的重要组分,实验室中通常采用重量法、火焰光度法及原子吸收法[1]等测定.而目前野外常用阴阳离子差减法计算水中钾钠的含量,... This article not only introduces the method of using ion selective electrode to test successively K +,Na + in natural water, but also discusses the testing system, interference of other substanes. The experiment shows that when the density of other ions in natural water is less than 10 -4 mol/L, the linear scope of potassium electrode is 8×10 -6 mol/L~10 -1 mol/L,and the linear scope of the sodium electrode is 8×10 -5 mol/L~10 -1 mol/L. Its result is almost consistent with flame photometer, its relative error is generally smaller than 5%.
作者 李运涛
出处 《陕西师范大学学报(自然科学版)》 CAS CSCD 北大核心 1997年第2期115-116,共2页 Journal of Shaanxi Normal University:Natural Science Edition
关键词 天然水 水分析 离子选择电极 ion selective electrode natural water K +,Na +