期刊文献+

PET/CT的技术性能及临床应用 被引量:15

Technical capacity and clinical application of PET/CT
下载PDF
导出
摘要 目的:介绍PET/CT的性能特点及临床应用。方法:对PET/CT的技术性能进行了分析,并对其发展趋势进行了展望。结果:PET能从分子水平上反映人体组织的生理、病理、生化、代谢改变;多排螺旋CT则可显示机体精细的解剖结构。结论:PET/CT可实现PET图像和CT图像的同机融合,形成2种技术的优势互补,具有极高的诊断性能和临床应用价值。 Objective To introduce the function characteristics and clinical application of PET/CT. Mothods The technical performance of PET/CT was analyzed and its development trend was expected. Results PET/CT reflected physiology, pathology, biochemistry and metabolism of physical tissue at molecule level, and multi-slice CT images displayed subtle anatomic structure. Conclusion PET/CT achieves the combination of PET and CT images, which have significant diagnosis capability and clinical application value.
机构地区 解放军第
出处 《医疗卫生装备》 CAS 2007年第10期59-60,62,共3页 Chinese Medical Equipment Journal
关键词 PET/CT 晶体探测器 衰减校正 放射治疗 临床应用 PET/CT crystalloid detector CTAC radiate treatment clinical application
  • 相关文献

参考文献8

二级参考文献53

  • 1陈盛祖.关于PET/CT与分子影像学[J].中华核医学杂志,2003,23(S1):11-12. 被引量:14
  • 2于金明,邢力刚,杨国仁.^(18)F-脱氧葡萄糖PET用于制定肿瘤放射治疗计划研究进展[J].中华放射肿瘤学杂志,2004,13(2):133-136. 被引量:20
  • 3孙晓蓉,邢力刚,于金明,付政,马莉,赵书强,陈鲁生,李文武,杨国仁.肺部肿瘤PET/CT同机图像融合精度研究[J].中华核医学杂志,2004,24(5):302-304. 被引量:11
  • 4Osman MM, Cohade C, Nakamoto Y, et al. Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients.J Nucl Med, 2003, 44: 240-243.
  • 5Nakamoto Y, Tatsumi M, Cohade C, et al. Accuracy of image fusion of normal upper abdominal organs visualized with PET/CT. Eur J Nucl Med Mol Imaging, 2003, 30: 597-602.
  • 6Nehmeh SA, Erdi YE, Ling CC, et al. Effect of respiratory gating on quantifying PET images of lung cancer. J Nucl Med, 2002, 43: 876-881.
  • 7Goerres GW, Kamel E, Heidelberg TN, et al. PET-CT image co-registration in the thorax: influence of respiration. Eur J Nucl Med, 2002,29: 351-360.
  • 8Beyer T, Antoch G, Blodgett T, et al. Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology. Eur J Nucl Med Mol Imaging, 2003, 30: 588-596.
  • 9International Commission on Radiation Unite and Measurements. Prescribing, recording, and reporting photon beam therapy: report 50, Washington, DC:ICRU, 1993.
  • 10International Commission on Radiation Unite and Measurements. Prescribing, recording, and reporting photon beam therapy: report 62, Washington, DC:ICRU, 1999.

共引文献74

同被引文献128

引证文献15

二级引证文献115

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部