期刊文献+

磁共振尿路成像(MRU)技术应用探讨 被引量:2

Exploration of magnetic resonance urography technique
下载PDF
导出
摘要 目的:探讨磁共振泌尿系成像(MRU)技术的临床适应证及临床意义。方法:行常规磁共振成像T1 WI及T2 WI轴位及T1 WI冠状位。然后用快速自旋回波重T2 WI加权序列扫描,图像经最大密度投影法重建。结果:20例中18例MRU影像均能满足诊断要求,2例患者检查前准备不充分,检查失败。结论:MRU特别适合尿路狭窄、梗阻及年龄大、体质差、碘过敏等不适宜静脉肾盂造影或静脉肾盂造影不显影的患者。 Objective To explore the clinical application and significance of Magnetic Resonance Urography. Methods T1WI and T2WI images in transverse section and TIWI images in coronary section were obtained. Then fast spiral echo sequence was used to get weighted T2WI images and the images were reconstructed with MIP (maximum intensity projection). Results Among the 20 cases, 18 MRU images met the diagnostic need, and 2 cases failed because of poor preparation. Conclusion MRU is suitable for the patients who are inappropriate to do IVP (intravenous pyelography), such as urinary tract restricted and obstructed, old people, poor physical condition and iodine allergy, or the patients who did IVP but there were no contrast agent discerned.
作者 张廉良
出处 《医疗卫生装备》 CAS 2007年第10期61-62,共2页 Chinese Medical Equipment Journal
关键词 磁共振 MRU 临床应用 Magnetic Resonance Magnetic Resonance Urography clinical application
  • 相关文献

参考文献2

二级参考文献7

共引文献1

同被引文献13

  • 1李澄,王礼同,汤晓明,颜虹,罗志刚,薛贞龙.多层螺旋CT曲面重建尿路成像技术的应用[J].放射学实践,2004,19(9):644-646. 被引量:20
  • 2蒋宇宏,刘海滨.静脉尿路造影术与MR水成像技术在泌尿系统疾病检查中的对比分析[J].中国中西医结合影像学杂志,2004,2(4):256-257. 被引量:5
  • 3黄正林,肖格林,余水全,刘锋,李水连,陈志明,郑建夫,傅万红.IVP显示不良后CT检查的价值[J].中国CT和MRI杂志,2005,3(3):51-53. 被引量:7
  • 4姜丽,贺声,张燕群,王占宇,梁英魁,郭勇,李小娟.16层螺旋CT泌尿系成像与CR静脉肾盂造影效果对比[J].医疗卫生装备,2006,27(12):55-57. 被引量:3
  • 5Rimondini A, Morra A, Bertolotto M, et al. Spiral CT with Multiplanar Reconstructions (MPRS) in the Evaluation of Ureteral Neoplasms: Preliminary Results. Radiol Med, 2001,101:459-465.
  • 6Reut her G,Kiefer B, Wandi E. Visualization of Urinary Tract Dilatation: Value of Single2shot MR Urography.Eur Radiol,1997, 7:1276-281.
  • 7Aert s P, Van Hoe L, Bosmans H,et al. Breat h2hold MR Urography Using t he HASTE Technique.AJ R,1996,155:543-545.
  • 8Nolte-Emstin C C,Wildberger J E,Borehe H.et al.Mult-slice CTU after diuretic injection:initial results[J].Rofo,2001,173(3):176-180.
  • 9Silverman S G,Akbar S A,Mortele K J.et al.Multi-detector row CTU of normal urinary collecting system:furosemide versus saline as adjunct to contrast medium[J].Radiology,2006,240(3):749-755.
  • 10Nino-Muricia M,Jeffrey Jr R B,Beaulieu C F,et al.Multidetector CT of the pancreas and bile duet system:value of curved planar reformation[J].AJR,2001,176(3):689-693.

引证文献2

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部