摘要
为准确预测雷管-导爆管之间的隔爆特性,提出了针对轴向爆轰作用下侧面隔板装药冲击起爆的理论分析方法,通过隔爆实验对该方法进行了验证。该方法可用于引信隔爆安全距离(角度)等设计参数的计算。
In period if an unintended explosive of detonator happen, the interrupter will effectively prevent the detonation transfer between detonator and lead. In order to predict the property of interrupting between detonator and lead, this paper gives a theory describing in^rrupting of the detonator shock waves in the fuze explosive Wain, the theory is verified by some experiments. It can be used to calculate parameters such as safe distance of interrupting in fuze.
出处
《火工品》
CAS
CSCD
北大核心
2007年第4期31-34,共4页
Initiators & Pyrotechnics
关键词
引信
雷管
冲击波
隔离
安全
Fuze
Detonator
Shock wave
Interrupt
Safety