摘要
水对纸质档案的损害导致在选择档案库房内灭火设施时必须减少其水渍损失,作为哈龙的替代品之一——细水雾灭火系统已被建议用于保护对水敏感的区域,如档案库房。通过试验研究了细水雾灭火系统控制与扑灭档案库房火灾的可能性,并比较不同喷头形式的细水雾灭火系统在扑救档案库房火灾中的局限性,为细水雾灭火系统在档案库房内的推广应用提出建议。
Water mist system(WMS)has been recommended as one for fire control at water and humidity sensitive circumstances to replace the Halon agents to reduce the damage of water stain. The feasibility and control of WMS applied for fire extinguishing in archival repository was researched experimentally. Also the limited function of various nozzles was investigated. Some recommendations deal with the WMS application for fire control of archival repositorv have been proposed.
出处
《给水排水》
CSCD
北大核心
2007年第10期76-81,共6页
Water & Wastewater Engineering
关键词
细水雾
喷头形式
纸质档案
灭火有效性
Water mist
Type of nozzles
Archives ~ Effectiveness of fire control