摘要 介绍了焦化厂爆炸危险区域的划分及防爆电气设备选型的方法,包括型式、类别、所处的级别和温度组别的确定等,电气设备的正确选型可有效防止电气火花引起的爆炸事故发生。 The classification of hazardous areas in coking plants and the selection of explosion-proof electrical equipment including the determination of their models, categories, grades and temperature groups were introduced. Through the right model selection of electrical equipment, explosive accident due to electrical sparks can be effectively prevented.
出处 《煤化工》 CAS 2007年第4期31-33,共3页 Coal Chemical Industry
关键词 焦化厂 防爆电气设备 选型 coking plant, hazardous area, explosion-proof electrical equipment, model selection
  • 相关文献

参考文献5

二级参考文献6

  • 1.GB50058--92.爆炸和火灾危险环境电气装置设计规范[S].,..
  • 2.HG20540--92.化肥厂电力设计技术规定[S].,..
  • 3.HG/T20664--1999.化工企业供电设计技术规定[S].,..
  • 4GB 50058-92.爆炸和火灾危险环境电气装置设计规范[S].,..
  • 5兵器工业第五设计研究院.工厂常用电气设备手册[M].北京:中国电力出版社,1998.