期刊文献+

350MW燃气轮机组煤气加热器螺栓断裂失效分析 被引量:11

Failure Analysis of Fractured Bolts on Coal Gas Heater of 350 MW Gas Turbines
下载PDF
导出
摘要 采用宏观和微观分析法对350 MW燃气轮机组煤气加热器盲板螺栓断裂进行了系统的表征分析。结果表明,螺栓的断裂是由于材质和加工质量不合格、螺栓紧固力不当以及环境介质的交互作用所产生的电偶腐蚀、缝隙腐蚀和随后的应力腐蚀开裂而引起的,并提出了防止螺栓断裂重复发生的相应对策。 The fracture of blind plate bolts on a coal gas heater of 350 MW gas turbine unit were systematically characterized and analyzed by a series of macroscopic and microscopic analysis methods. The results show that the fracture of the bolts was caused by galvanic corrosion, crevice corrosion and followed stress corrosion cracking ,which are resulted from interaction of inferior materials, poor processing quality, improper fastening way and environment medium. Countermeasures for preventing the fracture of bolts are also put forward.
出处 《金属热处理》 EI CAS CSCD 北大核心 2007年第10期88-92,共5页 Heat Treatment of Metals
关键词 螺栓 不锈钢 失效分析 缝隙腐蚀 应力腐蚀开裂 bolt stainless steel failure analysis crevice corrosion stress corrosion cracking
  • 相关文献

参考文献3

二级参考文献2

  • 1钢制压力容器分析设计资格考核细则[J]石油化工设备,1995(05).
  • 2GB 150-1998.钢制压力容器[S],1998.

共引文献5

同被引文献49

引证文献11

二级引证文献59