期刊文献+

输电线路放电声发射现象的试验 被引量:7

Experimental Research on Acoustic Emission of Discharge from the Power Transmission System
下载PDF
导出
摘要 试验研究了输电线路放电电脉冲、放电伴随声发射波及二者间的关系,在大量试验的基础上,总结了绝缘子的内部放电、绝缘子表面污秽放电、线路的尖端电晕、接触不良放电以及近区的雷电等不同形式放电伴随声发射波的特征。结果发现,利用放电电信号和声信号之间的相位差,可以实现输电线路放电源的声发射定位,利用不同形式放电声发射波的外形、周期性和对称性的差别,可以有效地识别放电的形式并进行故障诊断。 During the discharging process of the power transmission system, the electric impulses, the acoustic emission (AE) waves and the relation between them are studied by experiment in laboratory. Based on a large number of experiments the common characteristics of the AE wave of the interior discharge from the insulator, contaminant discharge from the insulator, corona from the transmission line, discharge from bad contact and thunderbolt are summarized, respectively. It is found that the discharge source can be located by means of the phase-shifting between the electric impulse and the acoustic emission wave of the same discharge. The type of discharge can also be identified through the difference in periodicity, the shape and the symmetry of the AE wave of discharge from the power transmission system.
出处 《电力系统自动化》 EI CSCD 北大核心 2007年第19期80-84,共5页 Automation of Electric Power Systems
基金 湖北省教育厅自然科学研究项目计划资助(D200613004)。~~
关键词 输电线路 放电 声发射 定位 识别 power transmission system discharge acoustic emission location] identification
  • 相关文献

参考文献13

二级参考文献34

共引文献171

同被引文献58

引证文献7

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部