摘要 A series of confined swell tests were conducted on a needle-punched geosynthetic clay liner (GCL) with tap water as the hydration medium. The effects of the static confining stress on the swelling characteristics of GCLs and the hydration time under different confining stresses were explored. Increasing the static confining stress led to: shorter hydration time; smaller final GCL height; less final GCL bulk void ratio; smaller final bentonite moisture content. The confined swell pressure determined for the tested GCL was 82.2 kPa, and the relationships between confining stress, final bulk void ratio (or final GCL height, final bentonite moisture content) were attained through the analyses of the confined swell test results in this study. A series of confined swell tests were conducted on a needle-punched geosynthetic clay liner (GCL) with tap water as the hydration medium. The effects of the static confining stress on the swelling characteristics of GCLs and the hydration time under different confining stresses were explored. Increasing the static confining stress led to: shorter hydration time; smaller final GCL height; less final GCL bulk void ratio; smaller final bentonite moisture content. The confined swell pressure determined for the tested GCL was 82.2 kPa, and the relationships between confining stress, final bulk void ratio (or final GCL height, final bentonite moisture content) were attained through the analyses of the confined swell test results in this study.
出处 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2007年第4期485-488,共4页 哈尔滨工业大学学报(英文版)
关键词 geosynthetic clay liner(GCL) needle-punched hydration swell confining stress 地理型人造粘土机 针式冲床 水合膨胀 限制的压力
  • 相关文献

参考文献5

  • 1LaGatta M B,Boardman B T,Cooley B H,et al.Geosyn- thetic clay liners subjected to differential settlement[].Jour- nal of Geotechnical and Geoenvironmental Engineering.1997
  • 2Ruhl J L,Daniel D E.Geosynthetic clay liners permeated with chemical solutions and leachates[].Journal of Geotech- nical and Geoenvironmental Engineering.1997
  • 3Petrov R J,Rowe R K,Quigley R M.Selected factors in- fluencing GCL hydraulic conductivity[].Journal of Geotech- nical and Geoenvironmental Engineering.1997
  • 4Lake C B,Rowe R K.Swelling characteristics of nee- dlepunched, thermally treated geosynthetic clay liners[].Geotextiles and Geomembranes.2000
  • 5Estornell,P,,Daniel,D.Hydraulic conductivity of three geosynthetic clay liners[].Journal ofGeotechnical EngineeringASCE.1992