期刊文献+

日本光电MEK-7222K全血细胞分析仪性能评价 被引量:2

Performances of MEK-7222K Hematology Analyzer
下载PDF
导出
摘要 目的:对日本光电MEK-7222K全血细胞分析仪的主要性能作初步评价。方法:按照国际血液学标准化委员会(ICSH)的有关规定对全血细胞指标进行测试。从精密度、总重复性、携带污染率、线性、白细胞分类结果与手工镜检的相关性、与SysmexXE-2100相关性以及仪器全血和预稀释两种计数模式之间的相关性等方面评价MEK-7222K全血细胞分析仪。结果:日本光电MEK-7222K全血细胞分析仪的批内、批间精密度CV值及总重复性CV值均在可接受范围内;各分析参数的携带污染率均<1%;线性良好;与SysmexXE-2100对比分析,所对比参数相关性良好;白细胞分类结果与手工镜检的相关性良好;全血和预稀释两种计数模式的相关性良好。结论:日本光电MEK-7222K全血细胞分析仪分析结果准确、可靠,仪器的各项主要性能都能满足临床的需要,可供国内大中小医院选用。 OBJECTIVE: To analyze the performances of MEK - 7222K hematology analyzer (Japan). METHODS: The evaluation was performed on the indices of complete blood cells by using guidelines established in the International Committee for Standard - ization Haematology (ICSH) document. The performances of MEK - 7222K hematology analyzer were evaluated from aspects of precision, total repeatability, carry - over rate, linearity, the correlation between the analyzer and microscope in leukocyte differential count, the its correlation to Sysmex XE- 2100 in detection results, and the correlation between the mode of whole blood and capillary vessel blood of the instrument. RESULTS: The CV value of within - and between- batch precision and that of the total repeatability were all within the designed range. The carry - over rate was lower than 1%. The linearity was good. The correlation between the instrument and microscope in leukocyte differential count, between the instrument and Sysmex XE - 2100 and between the mode of whole blood and capillary vessel blood of the instrument were all satisfactory. CONCLUSION: MEK - 7222K automatic hematology analyzer was proved to be accurate and reliable in test results, and the perfomances of the analyzer could all meet the clinical needs, which serves as a choice for large, medium, and small size hospitals in China.
出处 《中国医院用药评价与分析》 2007年第5期341-344,共4页 Evaluation and Analysis of Drug-use in Hospitals of China
关键词 全血细胞分析仪 仪器性能 评价 Hematology analyzer Performance of instrument Evaluation
  • 相关文献

参考文献2

  • 1International Council for Standardization in Haematology. Guidelines for the evaluation of blood cell analyzer including those used for differential leukocyte and reticulocyte counting and celt marker application. Prepared by the ICSH expert panel on cytometry[J]. Clin Lab Haemat, 1994,16:157.
  • 2National Committee for Clinical Laboratory Standards. Leukocyte Differential Counting NCCLS Approved Standard H20- A2[S] ,Villanova, PA, 1992.

同被引文献16

  • 1王松霞,韦涌涛,刘程,李武伦.BC-5500型全自动血液分析仪使用与评价[J].医学检验与临床,2008,20(2):105-105. 被引量:7
  • 2李永海,杨占双,李满库.五分类血液分析仪选型分析[J].黑龙江医药科学,2006,29(3):63-63. 被引量:3
  • 3李亚红,林志远,罗建伟.血细胞分析仪白细胞分类功能评价[J].国际检验医学杂志,2006,27(7):586-588. 被引量:8
  • 4张旭凯,陆海峰.五分类血液细胞分析仪的原理及应用[J].中国医疗器械信息,2006,12(10):52-56. 被引量:25
  • 5苏庆军,赵燕,陈建国,王丽霞,唐茂林,王红雷,葛德元.血液标本存放条件对检测结果的影响[J].华北国防医药,2007,19(3):55-57. 被引量:18
  • 6International Council for Standardization in Hematology. Guidelines for the evaluation of blood cell analyzer including those used for differential leukocyte and reticulocyte counting and cell marker application. Prepared by the ICSH expert panel on cvtometrv[J].Clin Lab Haemat.1994(16):157-174.
  • 7叶应妩,王毓三,申子王lji.伞国l临床榆.喻操作规程[M].3版.南京:东南大学出版社,2006:47—73.
  • 8International Council for Standardization in Haematology. Reference method for the enumerating of erythrocytes and leukocytes[ J]. Clin Lab Haemat,1994,16(2) :131 -138.
  • 9ICSH. Guidelines for the evaluation of blood cell analysers including those used for difi~rential leucocyte and reticulocyte counting and cell marker applications [ J ] Clin Lab Haemat, 1994,16(2) :157 - 174.
  • 10魏吴,丛玉隆.医学实验拳质垡管理与认可指南[M].北京:中国计量出版社,2004:59—63.