对哈三电厂3号机组凝汽器铜管频繁腐蚀泄漏的现状、腐蚀造成的原因及腐蚀机理进行了分析,从铜管的材质、沉积物、运行工况、检修操作、保养等方面进行了分析,采取相应措施,收到了良好的效果。
The corrosion situation and causes of the condenser copper pipes of the No.3 unit in Ha′rbin No.3 Power Plant are presented,and the copper pipe′s material,internal deposition,operational condition,maintenance and repair are analyzed.Relevant preventive measures were adopted with good effect obtained.
出处
《华东电力》
北大核心
2007年第9期80-82,共3页
East China Electric Power
关键词
凝汽器铜管
腐蚀
防护
condenser copper pipe
corrosion
protection