小动物SPECT-CT装置的研发 被引量:1

Development of SPECT-CT System for Small Animals
下载PDF
导出
摘要 本文介绍了一款用于小动物成像的SPECT-CT装置,它的主要特点是采用了多探头碲化锌镉(CZT)平板探测器的SPECT系统和高分辨率、微焦点、锥束X-CT系统,可实现滑环螺旋扫描和双核素SPECT成像,开放式的机架设计特别适合于基础医学研究、新药开发研究和药理学的研究。 This paper introduces a multi-modality imaging system of SPECT-CT for small animal. The gantry is configured with helical continuous scanning capability and an open architecture that will allow flexibility in configuring the imaging components when used for base medicine researching, development of new drug, and pharmacology researching.
出处 《医疗设备信息》 2007年第9期4-6,52,共4页 Information of Medical Equipment
关键词 双模式成像 SPECT X—CT 小动物成像 碲化锌镉(CZT) dual-modality imaging single-photon emission computed tomography X-ray computed tomography small-animal imaging Cadmium Zinc TeUuride (CZT).
  • 相关文献

参考文献10

  • 1耿茜,曹永胜,王皓.医学影像技术与创新[J].医疗设备信息,2004,19(1):1-3. 被引量:13
  • 2Matthew A.Kupinski,et al.,Small-Animal SPECT Imaging[M],Springer Verlag,June 2005:1-7.
  • 3S.R.Cherry,Y.Shao,R.W.Silverman,K.Meadors,MicroPET:a high resolution PET scanner for imaging small animals[J].IEEE Trans Nucl Sci.44,pp.1161-1166,1997.
  • 4F.A.Dilmanian,et al.,A high resolution SPECT system based on a multichannel-plate imager[J],IEEE Trans.Nucl.Sci.,vol.37,pp.687-695,1990.
  • 5D.P.McElroy,et al.,Evaluation of A-SPECT:A desktop pinhole SPECT system for small animal imaging,2002.
  • 6B.H.Hasegawa,et al.,Dual-modality inaging of function and physiology[J],Acad Radio 19 (2002),pp.1305□1321.
  • 7A.Goertzen.Design of a Simultaneous Combined PET-CT Imaging System for Mouse Imaging.in HiRes 2001:High Resolution Imaging in Small Animals:Instrumentation,Applications and Animal Handling[C],September 9-11,2001.
  • 8K.Iwata,et al.,Design and utility of a small animal CT/SPECT system[C],2001 IEEE Nucl.Sci.Symp.Conf.Rec.,vol.3,2002.
  • 9A.G.Weisenberger,et al.,SPECT-CT System for Small Animal Imaging[J],IEEE Trans.Nucl.Sci.,vol.50,pp.74,2003.
  • 10G.Sato,et al.,Characterization of CdTeCdZnTe detectors[J],IEEE Trans.Nucl.Sci.,49(2002)1258.

共引文献12

同被引文献8

  • 1马天予,周荣,吴朝霞,刘亚强,王石,金永杰.基于Monte Carlo模拟设计MicroSPECT针孔准直器[J].清华大学学报(自然科学版),2007,47(z1):933-936. 被引量:3
  • 2陈绍亮,赵军,石洪成,刘兴党,吴春英.第51届美国核医学年会概况[J].中华核医学杂志,2004,24(6):382-383. 被引量:4
  • 3Mitchell GS,Cherry SR.A high sensitivity small animal SPECT system[J].Phys Med Biol,2009,54(5):1291-1305.
  • 4Kim JS,Lee JS,Im KC,et al.Performance measurement of themicroPET focus 120 scanner[J]J Nucl Med,2007,48(9):1527- 1535.
  • 5Rowland DJ,Cherry SR.Small-animal preclinical nuclear medicine instrumentation and methodology[J].Semin Nucl Med,2008,38(3):209-222.
  • 6Tenney CR,Tornai MP,Smith MF,et al.Uranium pinhole collimators for 511-keV photon SPECT imaging of small volumes[J].IEEE Transactions on Nuclear Science,2001,48 (4): 1483-1489.
  • 7Zeniya T,Watabe H,Aoi T,et al.Use of a compact pixellated gamma camera for small animal pinhole SPECT imaging[J].AnnNucl Med,2006,20(6):409 - 416.
  • 8孟庆乐,杨瑞,曹艳,王自正,李少华,邵国强.SPECT/CT融合显像在^(99)Tc^m-MIBI甲状腺亲肿瘤显像中的应用[J].中国医疗设备,2014,29(2):121-122. 被引量:5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部