摘要
以某电厂循环流化床(CFB)锅炉的冷态试验情况为例,介绍CFB锅炉冷态试验项目、方法及各项试验的具体要求,并分项介绍准确的冷态试验方法对锅炉经济安全运行的重要意义。
Taking the situation of cold-state test for circulating fluidized bed(CFB) boiler in one power plant as example,the items,methods, and content of test items for cold-state test of CFB boilers have been presented,and the importance of accurate cold-state test method for economic and safe operation of the boiler being item by item expounded.
出处
《热力发电》
CAS
北大核心
2007年第10期27-29,共3页
Thermal Power Generation