起博器外露的处理方法及原因分析 被引量:3

The cause analysis and management of pacemaker exposure
下载PDF
导出
摘要 目的探讨起博器置入术后外露的处理方法及原因分析。方法先行起博器处分泌物的培养加药敏试验;然后切除感染皮肤,将起博器取出后用碘伏浸泡,同时清除腔隙内感染的肉芽组织和增生的纤维组织,用双氧水和甲硝唑液反复冲洗;于起博器上缘沿胸大肌的肌纤维走行,将胸大肌的肌纤维分开形成胸大肌、胸小肌腔隙,并将腔隙剥离得足够大,重新置入起博器;分层缝合切口后放置负压引流。结果自2000年1月至2006年12月,对6例起博器外露患者进行了处理,术后伤口均Ⅰ期愈合。随访患者3~6个月,无再次起博器外露及感染的发生。结论起博器外露其后果较严重,采用积极及适当的处理方法(将起博器置入胸大肌下)是减少并发症的发生、获得良好处理效果的关键。 Objective To investigate the cause and management of pacemaker exposure. Methods Secretion from the wound bed was cultured and antibiotic sensitivity test was performed preoperatively. During surgery, the infected skin was excised, paemaaker was taken out and sterilized by iodophor. Meanwhile, infected granulation tissue and hyperplasfic fibrous tissue inside the pocket were also cleared out. The wound was washed thoroughly by hydrogen dioxide and metronidazole solution. On the upper edge of pacemaker, the musculus peetoralis major was divided along the fiber, and a new pocket was undermined between the musculus pectoralis major and minor. The pacemaaker was inserted into the new pocket, the wound was closed by layers, and a suction drainage was put inside the pocket. Results From Jan. 2000 to Dec. 2006, a series of six patients was treated by this method. The wound- healed primarily. The patients were followed up for 3~6 months. There was no infection or re- exposure occurrence. Conclusion Although pacemaker exposure was a serious results, through aggressive treatment (insert the pacemaker underneath the musculus pectoralis major) can effectively reduce the occurrence of complications.
出处 《中国美容整形外科杂志》 CAS 2007年第5期363-364,共2页 Chinese Journal of Aesthetic and Plastic Surgery
关键词 起博器 外露原因 处理方法 Pacemaker Complication Treatmeat
  • 相关文献

参考文献7

二级参考文献17

  • 1冯义柏.心脏起搏器植入技术指南[J].中华心律失常学杂志,1998,2(3):217-224. 被引量:31
  • 2[1]FURMANS, HANES D L. A practic of cardiac pacing [ M ]. 2nd ed.Mount Kisco New York: Futura Publishing Co, 1989. 183-184.
  • 3[2]BAROLD S S. Morden cardiac pacing[M]. Mount Kisco New York:Futura Publishing Co, 1985.213-215.
  • 4[3]EL-SHERIF N, SAMET P. Cardiac pacing and electrophysiology [M]. 3rd ed. Philadelphia: London W. B Saunders Co, 1991. 167.
  • 5Byrd CL, Schwartz S J, Hedin N, et al. Lead extraction : indication and techniques. Cardiol Clin, 1992,10 ( 4 ) :735-748.
  • 6Mortensen PT, Sogaard P, Mansour H, et al. Sequential Biventricular Pacing: Evaluation of Safety and Efficacy.PACE, 2004, 27: 339-345.
  • 7Sanfilippo AJ,Abascal VM,Sheehan M,et al.Atrial enlargement as a consequence of atrial fibrillation:A prospective echocardiographic study[J].Circulation,1990,82(3):792-797.
  • 8Nielsen JC,Andersen HR,Thomsen PE,et al.Heart failure and echocardiographic changes during long-term follow-up of patients with sick sinus syndrome randomized to single-chamber atrial or ventricular pacing[J].Circulation,1998,97 (10):987-995.
  • 9Stierle U,Kruger D,Vincent AM,et al.An optimized AV delay algorithm for patients with intermittent atrioventricular conduction[J].Pacing Clin Electrophysiol,1998,21 (5):1035-1043.
  • 10Sweeney MO,Hellkamp AS,Ellenbogen KA,et al.Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction[J].Circulation,2003,107 (23):2932-2937.

共引文献125

同被引文献9

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部