期刊文献+

基于BP神经网络的矿井一氧化碳检测方法研究 被引量:4

Research on Detection of CO in Mine Based on BP Neural Network
下载PDF
导出
摘要 文章采用热催化传感器和电化学式气体传感器的配合使用,为了解决两种传感器对矿井一氧化碳和甲烷气体的"交叉敏感"问题,提出了一种基于BP神经网络技术的传感器系统。研究了采用两种传感器组成的多传感器阵列与BP神经网络相结合来实现一氧化碳气体浓度精确检测的方法。实验证明,利用基于BP神经网络的多传感器阵列模型,能有效的提高对井下一氧化碳气体的测量精度。 Because of the effect of methane gas to electrochemical sensor, precision of CO detection was reduced. In order to increase the precision of CO detection, electrochemical sensor was used with a catalytic sensor in this paper. Because there was the cross sensitivity of two sensors to CO and methane gas in mine, a gas sensor array system based on BP neural network and the method of signal processing on BP neural network for increasing precision of detection CO were researched in this paper. The experiment showed that the gas sensor array based on BP neural network could increase the precision of detection CO.
作者 叶小婷 汤劼
出处 《仪表技术》 2007年第10期40-42,共3页 Instrumentation Technology
关键词 CO检测 交叉敏感 信息融合 BP神经网络 CO detection cross sensitivity information fusion BP neural network
  • 相关文献

参考文献1

二级参考文献8

  • 1Lang Hong,IEEE Trans AES,1993年,29卷,2期,435页
  • 2Tao Li,IEEE Trans AES,1993年,29卷,4期,1251页
  • 3王泽和,现代军事,1992年,7卷,74页
  • 4团体著者,1992年
  • 5Lang Hong,1990年
  • 6Luo R C,1989年
  • 7Luo R C,1988年
  • 8Luo R C,1987年

共引文献155

同被引文献43

  • 1马学童,马奎,王磊.多组份气体定量检测研究[J].仪器仪表学报,2001,22(z1):58-59. 被引量:6
  • 2高大启,杨根兴.嗅觉模拟技术综述[J].电子学报,2001,29(z1):1749-1752. 被引量:7
  • 3聂雪梅,刘仲明,张水华,王启军.电子鼻及其在食品领域的应用[J].传感器技术,2004,23(10):1-3. 被引量:37
  • 4高峰,董海鹰,胡彦奎.基于BP神经网络的传感器交叉敏感性抑制[J].传感器技术,2005,24(2):22-23. 被引量:8
  • 5胡茜,葛思擘,王伊卿,李伟.电化学气敏传感器的原理及其应用[J].仪表技术与传感器,2007(5):77-78. 被引量:24
  • 6GARDNER J W, BARTLET'I' P N. A brief history of elec- tronic nose[J]. Sensors and Actuators B, 1994,18(1-3): 211-220.
  • 7SCHALLER E,BOSSER J O,ESCHER F. Electronic Noses and their application to food.Lebensmittel-Wissenschaft und- Technologie, 1994,31 (g): 305 - 316.
  • 8EKLOV T, LUNDSTROM I. Gas mixture analysis using a distributed chemical sensor system, Sensors and Actuators B, 1999,57:274-282.
  • 9HUYBERECHTS G, SZECOWKA P, ROGGEN J, et al. Simultaneous quantification of carbon monoxide and meth~ ane in humid air using a sensor array and an artificial neural network[J].Sensors and Actuators B,1997,45(2): 123-130.
  • 10SZCZUREK A, SZECOWKA P M, LICZNERS B W. Application of sensor array and neural networks for quan-tification of organic solvent vapours in air[J].Sensors and Actuators B, 1999,58:427-432.

引证文献4