摘要
将流动注射-氢化物发生和原子吸收光谱法有机的结合起来,探讨了流动注射-氢化物发生-原子吸收光谱法测定香烟接装纸中砷的最佳条件。样品经消解后,加入还原剂,使五价砷还原为三价,在盐酸介质中和硼氢化钾反应生成砷化氢,进入电热石英管原子化测定。检测结果相对标准偏差小于5%,加标回收率为96.7%~104%,方法检出限为0.18μg/L。
A method for determination of As in the cigarette tipping paper by using flow injection-hydride generation atomic absorption spectrometry (FI-HG-AAS) was proposed. The As(Ⅴ ) in the digested sample was firstly reduced to As( Ⅲ ) and then was reacted with KBH4 in hydrochloric acid to produce AsH3 for AAS determination. The relative standard deviation (RSD) was less than 5%, the recoveries was in the range of 96.7%-104%, and the detection limit for As was 0.18 μg/L.
出处
《分析科学学报》
CAS
CSCD
2007年第5期613-615,共3页
Journal of Analytical Science
基金
温州市科技局一般工业科研项目(G2006012)
关键词
流动注射-氢化物发生原子吸收光谱法
砷
香烟接装纸
Flow injection-Hydride generation atomic absorption spectrometry
Trace arsenic
The cigarette tipping paper