摘要
采用内电解法对081特种难降解特种废水进行试验研究,分析了废水来源及水质情况,对内电解法反应机理进行了介绍,总结了不同pH值、不同碳铁比、不同接触时间、不同进水COD对废水COD去除率的影响,为后续处理创造了条件。
utilizing internal electrolysis method experimental study is made on 081-special difficuldy degraded organic waste water. Based upon analysis of the origin and water quality situations of waste water the reaction mechanism of internal electrolysis is introduced. The influences of the changes of PH value, carbon-iron ratio, contact time, COD of inlet and removal ration of COD in waste water are summarized, which provide conditions for subsequent treatment.
出处
《山西建筑》
2007年第31期169-170,共2页
Shanxi Architecture
关键词
内电解
难降解
焦炭
铸铁屑
internal electrolysis, difficult degradation, coke, cast-iron scrap