摘要
对使用过的两种计算方法——平方根法和不均匀系数法的优缺点进行了介绍,根据管道直饮水的实际使用特点,提出了一种适合直饮水设计秒流量的计算新方法和相应的参数,新旧计算方法的计算结果对比分析表明:该新方法合理可靠,安全可信。
The advantages and disadvantages of two used methods: root-squaring method and non-uniform coeffident method are introduced according to the use features of direct-drinking water one new method is proposed for design flowrate calculation as well as related parameters Comparative analysis show calculation result of new method is reliable and credible.
出处
《山西建筑》
2007年第31期171-172,共2页
Shanxi Architecture
关键词
管道直饮水
设计秒流量
新方法