摘要 研究了以河砂和锰砂为填料时,接触氧化滤柱对铁锰的去除效果以及反冲洗对去除效果的影响.结果表明,在滤速为8.3m/h、进水pH值为6.8、溶解氧为1.7mg/L的条件下,河砂填料和锰砂填料滤柱对铁的去除效果分别需要9d和2d即可稳定,出水铁浓度均在0.3mg/L以下;河砂填料和锰砂填料滤柱对锰的去除效果分别需要48d和16d方可稳定,出水锰浓度均在0.1mg/L以下.反冲洗之后,河砂滤柱对铁和锰的去除能力需要40min和80min才能完全恢复;锰砂滤柱对铁、锰的去除能力需要20min和40min才能完全恢复.扫描电境对滤膜形态分析表明,成熟的除铁锰滤膜表面呈絮状,反冲洗之后滤料表面仍然附着有絮状滤膜,该絮状滤膜是反冲洗后除铁锰效果能够快速恢复的基础.实际工程中可以采取价格便宜的河砂取代锰砂,由此可以节省填料投资的90%. Fe and Mn removal from groundwater by a contact oxidation process and the effects of backwash were studied. It takes 9 days to have stable Fe removal with a filter chamber filled with sand and 2 days for the filter chamber of manganese mineral filtration. Forty-eight days are needed to have stable Mn reinoval with a filter chamber filled with sand, and 2 days for a filter chamber of manganese mineral filtration. Forty minutes and eighty minutes are needed for the filter chamber filled with sand to recover the ability of Fe and Mn removal after backwash. Twenty minutes and forty minutes are needed for the filter chamber of manganese mineral filling to recover the ability of Fe and Mn removal after backwash. SEM photographs show that floculations adhere to the surface of the filter membrane, that is the basis for quick recover of Feoand Mn after backwashing. Manganese mineral can be replaced by the cheaper sand as filling. In doing so, the investment can be greatly decreased.
出处 《山东大学学报(工学版)》 CAS 2007年第5期99-102,共4页 Journal of Shandong University(Engineering Science)
关键词 除铁 除锰 接触氧化滤柱 河砂 锰砂 iron removal manganese removal contact oxidation process sand manganese mineral
  • 相关文献

参考文献8

二级参考文献13

  • 1许保玖.给水处理[M].北京:中国建筑工业出版社,1979.94-119.
  • 2姚继贤.LLY高效过滤器的机理与实验研究[J].中国东北电力学院学报,1990,(2).
  • 3周利.软填料新型过滤器地下水除铁除锰的试验与研究(硕士毕业论文)[M].,1993..
  • 4上海市政工程设计院.给排水设计手册(第三册)[M].北京:中国建筑工业出版社,1986.894-913.
  • 5李奎白 刘超.地下水除铁除锰(第二版)[M].北京:中国建筑工业出版社,1989.4-12.
  • 6Mark M. Benjamin, Ronald S. Sletten et al. Sorption and Filtration of Metals Using Iron-Oxide-Coated Sand[J]. Water. Research, 1996, 30(11) :2609 - 2620.
  • 7李圭白 刘超.地下水除铁除锰[M].北京:中国建筑工业出版社,1987..
  • 8于连群,肖举强,付俊国,李桂荣.活化沸石除铁性能研究[J].铁道劳动安全卫生与环保,1997,24(2):98-101. 被引量:6
  • 9张杰,戴镇生.强氧化剂除锰原理与应用[J].给水排水,1997,23(3):16-18. 被引量:18
  • 10鲍志戎,孙书菊,王国彦,李惟,徐爱军,杨宏,于尔捷,张杰.自来水厂除锰滤砂的催化活性分析[J].环境科学,1997,18(1):38-41. 被引量:36

共引文献72

同被引文献16

引证文献1

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部