溶液全热回收装置及其优化分析 被引量:7

OPTIMIZATION ANALYSIS ON ENTHALPY RECOVERY DEVICE USING LIQUID DESICCANT
下载PDF
导出
摘要 分析了制约现有溶液全热回收装置效率的主要因素,以内部驱动势分布均匀一致为原则,对溶液全热回收装置进行了优化分析,并给出了在不增加装置体积投入的前提下,提高热回收装置效率的有效措施。构建了溶液全热回收装置最高可达效率的处理流程,并分析实际装置接近可达效率的程度。 By using liquid desiccant as the working media, the total heat energy exchange between outdoor air and indoor exhaust air can be realized, and cross-contamination can be avoided. The main factors which restrict the enthalpy recovery efficiency were analyzed, and the optimization analysis on the enthalpy recovery device using liquid desiccant was then presented based on the principle of uniform heat and mass transfer driving force. The effective method to improve recovery efficiency and the maximal reachable efficiency with certain mass flow rate and NTU value were constructed, and the difference between real and ideal device was also disussed.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2007年第7期762-768,共7页 Acta Energiae Solaris Sinica
基金 国家自然科学基金(50276029) 高等学校博士学科点专项科研基金(20050003051)
关键词 除湿溶液 全热回收 均匀性因子 性能优化 liquid desiccant enthalpy recovery uniform factor optimization analysis
  • 相关文献

参考文献9

二级参考文献32

  • 1电子工业部第十设计院主编.空气调节设计手册(第2版)[M].北京:中国建筑工业出版社,2000..
  • 2铃木谦一郎 大矢信男著 李先瑞译.除湿设计[M].北京:中国建筑工业出版社,1983..
  • 31,ASHRAE Standard 62-1999. Ventilation for acceptable indoor air quality. Atlanta, GA, American Society of Heating,Refrigerating and Air-Conditioning Engineers,1999.
  • 42,CEN. Ventilation for buildings: design criteria for the indoor environment. Brussels, European Committee for Standardization(CR 1752), 1998.
  • 53,ECA(European Concerted Action “Indoor air quality and its impact on man”). Guidelines for ventilation requirements in buildings.Luxembourg, Office for Official Publications of the European Communities(Report No.11,EUR 14449EN), 1992.
  • 64,Fisk W J, Mendell M J, Daisey J M, et al. The California healthy building study, Phase 1: a summary. In: Proceedings of Indoor Air'93, 1993, Vol.1,279-284.
  • 75,Mendell M J. Non-specific symptoms in office workers: a review and summary of the epidemiologic literature. Indoor Air, 1993,(3):227-236.
  • 86,Sundell J. On the association between building ventilation characteristics, some indoor environmental exposures, some allergic manifestations and subjective symptom reports. Indoor Air, 1994,Supplement No.2.
  • 97,Bluyssen P M, de Oliveira Fernandes E, Groes L, et al.European indoor air quality audit project in 56 office buildings. Indoor Air, 1996,(6):221-238.
  • 108,Wargocki P, Wyon D P, Baik Y K, et al. Perceived air quality, sick building syndrome(SBS)symptoms and productivity in an office with two different pollution loads. Indoor Air, 1999,9(3):165-179.

共引文献81

同被引文献51

引证文献7

二级引证文献53

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部