期刊文献+

Eye Model for Inspecting the Image Quality of IOLs

Eye Model for Inspecting the Image Quality of IOLs
下载PDF
导出
摘要 Purpose:To inspect and compare the image quality of an aspheric intraocular lens(IQ,Alcon)with those of conventional monofocal silicone and acrylic intraocular lens and multifocal intraocular lens(Array).Methods:The IOLs were tested in the eye model,which was designed to be optically equivalent to the theoretical eye model.The eye model is a combination of a spherical photographic lens with 35 mm focal length(IOL put in a water cell)and a charge coupled device(CCD)camera.The images constructed by the lenses are observed on a monitor of personal computer and the contrasts of the images are analyzed by using commercial image processing software.SHARP value is used to measure and estimate image definition.Results:The images constructed by changing the diameter of aperture stop and IOL.Observed by this eye model,the image definition of aspheric intraocular lens(IQ,Alcon)is better than others.Discussion:The proposed eye model is useful for testing functional vision and for inspecting the differences of intraocular lens. Purpose: To inspect and compare the image quality of an aspheric intraocular lens (IQ, Alcon) with those of conventional monofocal silicone and acrylic intraocular lens and muhifocal intraocular lens (Array). Methods: The IOLs were tested in the eye model, which was designed to be optically equivalent to the theoretical eye model. The eye model is a combination of a spherical photographic lens with 35 mm focal length (IOL put in a water cell) and a charge coupled device (CCD) camera. The images constructed by the lenses are observed on a monitor of personal computer and the contrasts of the images are analyzed by using commercial image processing software. SHARP value is used to measure and estimate image definition. Results : The images constructed by changing the diameter of aperture stop and IOL. Observed by this eye model, the image definition of aspheric intraocular lens (IQ, Alcon) is better than others. Discussion: The proposed eye model is useful for testing functional vision and for inspecting the differences of intraocular lens.
出处 《眼科学报》 2007年第3期172-180,共9页 Eye Science
关键词 晶状体 调制传递函数 对比敏感度 眼睛模型 图象质量 Eye model Intraocular lens (IOL) Modulation transfer function (MTF) Contrast sensitivity (CS)
  • 相关文献

参考文献1

二级参考文献6

  • 1Ng Kuang Chern,Aun Neow Poo,Marcelo H,et al.Practical issues in pixel-based autofocusing for machine vision[C].Seoul,Korea:Proceedings of the 2001 IEEE,International Conference on Robotics and Automation,2001.2791-2796.
  • 2Yoon Kim,Lee J S,Morales A,et al.A video camera system with enhanced zoom tracking and auto white balance[J].IEEE Transactions on Consumer Electronics,2002,48(3):428-434.
  • 3Ets S P,Luo J.Ground truth for training and evaluation of automatic main subject detection[C].Proceeding SPIE Conference on Human Vision and Electronic Imaging,2000.434-442.
  • 4Subbarao M,Choi T S,Nikzad A.Focusing techniques[J].Optical Engineering,1993,32(11):2824-2836.
  • 5李奇,徐之海,冯华君,戴顺林,边美娟.数字成象系统自动对焦区域设计[J].光子学报,2002,31(1):63-66. 被引量:18
  • 6朱倩,陈金华,李峰.基于图像分析的数码相机对焦技术研究[J].江苏大学学报(自然科学版),2003,24(4):61-64. 被引量:5

共引文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部