摘要 研究单通道FVEP信号提取的综合分析方法及其应用。考虑单通道FVEP信号提取的特殊性,引入了参考源通道以满足独立分量分析的应用条件,从而实现单通道FVEP信号与背景EEG噪声的分离;考虑参考源通道与实际检测中的背景噪声不完全匹配而可能带来的消噪效果不理想的问题,利用叠加平均技术与叠加次数的平方根成正比的特性,通过少次的叠加来进一步提高单通道FVEP信号的信噪比;最后利用多分辨率小波变换的多分辨率特性,实现FVEP信号的有效提取。此方法用于虚拟式颅内压无创检测分析仪的临床实验证明了本方法在实现颅内压无创检测方面的有效性。 In this article, the synthesis analysis method for the extraction of single channel flash visual evoked potential (FVEP) signal has been studied. Considering the particularity of single channel FVEP signal extraction, the reference source was introduced to satisfy the applying conditions of ICA, then the single channel FVEP signal and background EEG noise were separated preliminarily; and the SNR of FVEP signal were improved by taking advantage of assembly average method; finally FVEP signal was extracted efficiently with multi-resolution wavelet transform. Based on the synthesis method, the instrument for non-invasive detection of virtual intracranial pressure (ICP) was developed. Clinical experiments proved the efficiency of the proposed method and the instrument.
出处 《中国生物医学工程学报》 CAS CSCD 北大核心 2007年第5期713-718,共6页 Chinese Journal of Biomedical Engineering
基金 国家自然科学基金资助项目(50575233) 中国博士后科学基金项目(2005037549)
关键词 单通道 独立分量分析 参考源 小波变换 颅内压 single channel ICA reference source wavelet transform ICP
  • 相关文献

参考文献14

  • 1张丹,彭国光,董为伟.无创性颅内压监测技术研究进展[J].国外医学(脑血管疾病分册),2000,8(4):234-237. 被引量:20
  • 2Olson JE, Mishler L. blood chemistry, and pathology in a model of cerebral edema [ J]. Ann Emerg Med, Dimlich RV Brain Blood Volume, 1990,19: 1113- 1121.
  • 3Thomas BJ, Ward LC, Cornish BH. Spectrometry in the Determination of Body Compartmentsaa: Bioimpedance Accuracy and Clinical Significance[J]. Appl Radiat Isot., 1998, 49: 447- 455.
  • 4York DH, Puniam MW, Rosenfeld JG, et al. Relationship between visual evoked potentials and intracranial pressure[ J]. Neurosurg, 1981, 55(6) :909 - 916.
  • 5York D, Legan M, Benner S, et al. Further studies with a noninvasive method of intracranial pressure estimation [ J ].Neurosurgery, 1984,14(4) : 456 - 461.
  • 6Sjostrom A, Uvebrant P, Roos A. The light-flash-evoked response as a possible indicator of increased intracranial pressure in hydrocephalus[J]. Childs Nerv Syst., 1995,11(7) : 381 - 387.
  • 7洪波,唐庆玉,杨福生,潘映辐,陈葵,铁艳梅.ICA在视觉诱发电位的少次提取与波形分析中的应用[J].中国生物医学工程学报,2000,19(3):334-341. 被引量:52
  • 8Squires KC. Beyond averaging : the use of discriminant functions to recognize event related potentials elicited by single auditory stimuli [J]. Electroencephalograph Clinical Neurophysiology, 1976, 41: 449 - 459.
  • 9Liu WQ, Francis HYC, Lam FK, et al. Wavelet based methods for tracking the latency of evoked potentials [ A ]. In: Proceedings of IEEE-EMBS 17^th Annual Conference[ C ]. Montreal: IEEE-EMBS, 1995, 2:1061 - 1062.
  • 10Guthkelch AN, Sclabassi RJ, Hirsch RP, et al. Visual evoked potentials in hydrocephalus: relationship to head size, shunting, and mental development [ J]. Neurosurgery, 1984, 14 ( 3 ) : 283 - 286.

二级参考文献6

  • 1Comon P. Independent component analysis, a new concept? [J]. Signal Processing, 1994, 36 (3): 287-314.
  • 2Wei Q, Fung K. Adaptive filtering of evoked potentials with radial-basis-function neural network prefilter[J]. IEEE Trans on Biomedical Engineering, 2002,49(3).223-232.
  • 3Gish H, Cochran D. Generalized coherence [A]. International Conference on Acoustics, Speech, and Signal Processing [C]. New York: IEEE, 1988. 2745-2748.
  • 4B. G. Carter,A. Taylor,W. Butt. Severe brain injury in children: long-term outcome and its prediction using somatosensory evoked potentials (SEPs)[J] 1999,Intensive Care Medicine(7):722~728
  • 5张继武,郑崇勋,耿中行.用奇异性检测技术提取诱发电位[J].中国生物医学工程学报,1999,18(3):295-303. 被引量:13
  • 6洪波,唐庆玉,杨福生,潘映辐,陈葵,铁艳梅.ICA在视觉诱发电位的少次提取与波形分析中的应用[J].中国生物医学工程学报,2000,19(3):334-341. 被引量:52

共引文献69

同被引文献77

引证文献5

二级引证文献26

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部