基于大系统分解协调原理,采用遗传寻优算法,立足多谐波源网络中各节点谐波综合抑制的角度,依据电容器安装容量最小原则,考虑所有网络运行参量处于某一特定运行等级的静态组合,提出无源滤波器安装点及额定参数的优化选择方法,给出了整体分级递阶算法,并实例分析说明了整体算法的有效性。
A hierarchical genetic algorithm based ondecomposition-coordination principle of large scale systems isproposed, which is used to optimally select passive filters'locations and rated parameters in a network where alloperating variables are on a certain static operating level. Theobjective is to minimize total fixed capacity of capacitors basedupon harmonic suppression synthetically of all buses. Thewhole algorithm has been tested on a 30-bus distributionsystem with very promising result.
出处
《电网技术》
EI
CSCD
北大核心
1997年第4期45-48,共4页
Power System Technology
关键词
遗传算法
谐波
滤波器
电力系统
Genetic algorithm Harmonic Passive filter Optimal placement