摘要
分析了300MW汽轮机高压缸通流部分故障与热力过程参数的关系,提出了对汽轮机通流部分故障分层次模糊诊断的方法,并用电厂运行中采集到的实际故障参数对这种方法进行了考核,得到了比较满意的结果。
After analyzing the relationship between failures of 300MW turbine steam path components and variations thermal parameters, the paper proposes hierarchic fuzzy method of diagnosis. Diagnostic results obtained by this method compared with actual power plant parameters at failure, show relatively satisfying conformity.
出处
《动力工程》
CSCD
1997年第3期5-8,共4页
Power Engineering