350MW机组锅炉水平烟道烟温偏差调整试验

Adjusting Experiments on Horizontal Flue Gas Temperature Imbalance in 350MW Boiler
下载PDF
导出
摘要 本文分析了四角切圆燃烧水平烟道烟温偏差的成因,针对宝钢自备电厂2号锅炉三再超温爆管现象,通过燃烧调整,使二再、三再出口烟温偏差得到了明显改善,降低了水平烟道热力不均匀性,使再热器恢复汽温运行成为可能。 This paper analyzes the causes of horizontal flue gas temperature imbalance in T-firing system. In light of tube failure resulting from overheating in final reheater of Unit # 2 boiler in Baogang power plant, firing adjustment siguificantly improves the flue gas temperature imbalance at outlets of secondary reheater and final reheater which reduce the thermal irregularity in horizontal flue pass and make it possible to restore the reheater into dteam temperature operation.
出处 《锅炉技术》 北大核心 1997年第5期5-7,32,共4页 Boiler Technology
关键词 烟温偏差 爆管 调整 电站锅炉 烟道 水平烟道 Boiler, Flue gas temperature imbalance, Tube failure caused by overheating, Adjusting experiments
  • 相关文献

参考文献1

二级参考文献6

  • 1曹汉鼎,朱智士,张毓明.SG50412型(400吨/时)锅炉汽温攻关的试验研究[J]发电设备,1987(02).
  • 2王孟浩,杨宗煊,何沛霖.屏式过热器同屏热偏差的成因和计算方法[J]动力工程,1986(06).
  • 3曹汉鼎.大容量电站锅炉汽温问题分析及计算方法的研究(一)[J]锅炉技术,1986(01).
  • 4曹汉鼎.上锅SG50412型400吨/时锅炉炉膛计算方法的研究[J]上海机械学院学报,1984(02).
  • 5王孟浩,陈国雄.复杂过热器连接系统流量偏差的计算[J]动力工程,1983(04).
  • 6陈之航,赵再三.单相流体在并联管组中的流量分布和热偏差的理论及计算[J]锅炉技术,1974(10).