摘要
采用时域有限差分法评价了1GHz以内吉赫兹横电磁波(GTEM)小室的交叉极化特性和三维场均匀性.根据IEC61000-4-20标准,采用9点网格法分别对测试区的1/3和1/2内导体高度区的场分布特性进行了宽频带分析,并以测试区中心截面的名义场强为参考评估了沿纵向的场均匀性.计算结果表明:在1/3内导体高度区,三维场均匀性满足6dB限制,但工作频率超过一定频带后,交叉极化分量满足小于主分量6dB要求较为困难;随频率和测试区的增大,交叉极化特性和场均匀性下降,但较易满足放松要求.经实验证实计算结果准确可靠.
Both cross-polar coupling and three-dimensional field uniformity of gigahertz transverse electromagnetic (GTEM) cell were evaluated using finite-difference time-domain (FDTD) method at frequencies of up to 1 GHz. A 9-point grid was used to analyze the characterization of electric field distribution within the 1/3 and 1/2 septum height area of the test volume respectively in broad frequency band range according to IEC standard 61000-4-20. The numerical results show that within the 1/3 septum height area, the three-dimensional field uniformity fulfills the required 6 dB limit, but out of certain frequency band the cross-polar components are difficult to meet the 6 dB requirement relative to the primary field strength; moreover, with the increase of frequency or test volume, the cross-polarization performance and field uniformity will degrade but they are relatively easy to satisfy the relaxed requirements. The obtained results are validated by measurements.
出处
《东南大学学报(自然科学版)》
EI
CAS
CSCD
北大核心
2007年第5期756-760,共5页
Journal of Southeast University:Natural Science Edition
基金
福建省青年科技人才创新基金资助项目(2004J025)
关键词
电磁兼容
GTEM小室
时域有限差分法
交叉极化
场均匀性
electromagnetic compatibility (EMC)
gigahertz transverse electromagnetic (GTEM) cell
finite-difference time-domain method
cross-polarization
field uniformity