期刊文献+

麻醉深度的听觉诱发脑电提取技术

Methods of Extracting AEP for Monitoring the Anesthetic Depth
下载PDF
导出
摘要 大量研究证明听觉诱发电位(AEP)在麻醉深度监测方面的临床意义.本文论述了移动平均模式(MTA)和外因输入自回归模式(ARX)提取AEP的原理,通过对两种提取听觉诱发电位的研究证明,ARX模式更能满足临床麻醉深度监测的实时性要求。  Many researches have proved that auditory evoked potentials(AEP)can indicate the depth of anesthesia in the clinical practice.This paper introduces two methods of extracting AEP:the moving time average(MTA)model and the autoregressive model with exogenous input(ARX).In our study we used both the MTA model and the ARX model to extract AEP and the results show that using the ARX model can get the results significantly faster than using the MTA model,and the ARX model is more suitable for the real-time monitoring of the anesthetic depth.
出处 《中国医疗器械杂志》 CAS 2007年第5期330-332,共3页 Chinese Journal of Medical Instrumentation
基金 上海市教委科研基金项目
关键词 听觉诱发电位(AEP) 麻醉深度 移动平均模式(MTA) 外因输入自回归模式(ARX) auditory evoked potential(AEP) anesthetic depth moving time average model(MTA) autoregressive model with exogenous input(ARX)
  • 相关文献

参考文献8

二级参考文献31

  • 1潘映福.临床诱发电位学[M].北京:人民卫生出版社,1988.352.
  • 2Litvan H,Jensen EW,Revuelta M,et al. Comparison of auditory evoked potentials and the A-line ARX Index for monitoring the hypnotic level during sevoflurane and propofol induction. Acta anaesthesiol Scand, 2002, 46:245.
  • 3Jensen EW,Nygaard M,Henneberg SW. On-line analysis of middle latency auditory evoked potentials (MLAEP)for monitoring depth of anaesthesia in laboratory rats.Med Eng Phys, 1998,20:722.
  • 4Mantzaridis H,Kenny GN. Auditory evoked potential index: a quantitative measure of changes in auditory evoked potentials during general anaesthesia. Anaesthesia, 1997,52 : 1030.
  • 5Gajraj RJ,Doi M,Mantzaridis H, et al. Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness. Br J Anaesth, 1998,80: 46.
  • 6Iselin-Chaves IA,Moalem HE EI,Gan TJ, et al. Changes in the auditory evoked potentials and the bispectral index following propofol or propofol and alfentanil. Anesthesiology, 2000,92:1300.
  • 7Bailey PL,Egan TD,Stanley TH. Intravenous opioid anesthetics. In Miller RD, eds. Anesthesia, 5th ed. Philadelphia : Churchill Livingstone, 2000. 274.
  • 8Absalom AR,Sutcliffe N,Kenny GN. Effects of the auditory stimuli of an auditory potential system on level of consciousness, and on the bispectral index. Br J Anaesth,2001,87: 778.
  • 9Desmedt JE. Neural generators of somatosensory evoked potential components in human beings. In: Nordar RH, Barber C, ed.Evoked potentials Ⅱ. Boston: Butterworth Publishers. 1984. 39- 50.
  • 10Epstein NE, Danco J, Nardi D. Evaluation of intraoperative somatosensory-evoked potential monitoring during 100 cervical operations. Spine, 1993,18: 737-747.

共引文献58