摘要
传统的单片机由于受运算速度和精度的限制,难以完成电力系统对精确性和实时性的要求。本文设计了一种带电力监测的无功动态补偿装置,采用"龙腾S1"为总控制器,克服了传统单片机计算速度慢、精度低的缺陷。并能实时监测电网中的各项指标,在满足无功补偿的前提下,防止误动作,从而可有效避免重大事故的发生。
Traditional MCU can not complete the requirement s of power system which demands accuracy and real-time. A dynamic VAR compensation installation with power monitoring is designed in the paper. The installation adopts "LONGTENG SI" as main cont roller as it can compute and measure more quickly and accurately than traditional MCU. The system can measure the factors of power system. Based on the satisfaction of decreasing power factor, it can avoid the disoperation so that the serious accident could be avoided.
出处
《微计算机信息》
北大核心
2007年第32期155-156,175,共3页
Control & Automation
基金
黑龙江省教育厅科学技术研究基金项目(10551330)
关键词
无功补偿
工控机
SOC
Var compensation,Industrial compute,SOC